Purpose: Most surgeons divide the renal vein with a laparoscopic stapler during laparoscopic donor nephrectomy. The right renal vein is usually shorter than the left one and using the stapler on the right side can result in a higher incidence of vascular complications for right kidney recipients. We present our experience with a new technique for hand assisted laparoscopic right donor nephrectomy.
Materials And Methods: We designed a new vascular clamp to be completely inserted into the peritoneal cavity through the hand port incision in hand assisted laparoscopy. The renal vein with a cuff of the inferior vena cava was then excised. The defect in the inferior vena cava was sutured intracorporeally.
Results: A total of 80 kidney donors underwent hand assisted laparoscopic right donor nephrectomy using the new technique. Mean +/- SD operative time was 184 +/- 36 minutes. Operative time was decreased in the last 30 patients to 152 +/- 22 minutes. Intracorporeal suture time on the inferior vena cava was 16 +/- 3 minutes. No intraoperative complications were noted and there was no partial or total graft loss. Mean blood loss was 50 +/- 35 cc. Mean warm ischemia time was 4 +/- 2 minutes. Hospital discharge was on postoperative day 1 or 2 in 81% of patients. Graft function was normal in 78 recipients with a day 5 postoperative serum creatinine of 1.6 +/- 0.9 mg/dl. Two recipients showed delayed graft function and were treated medically.
Conclusions: This technique for hand assisted laparoscopic right donor nephrectomy has proved to be safe and reproducible. We recommend practicing laparoscopic inferior vena cava suturing in the animal laboratory before performing it in humans.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.juro.2007.07.005 | DOI Listing |
PLOS Digit Health
January 2025
Centre Référent Maladies Rares Neuromusculaires, Service de Médecine Physique et de Réadaptation Pédiatrique des Hospices Civils de Lyon - Hôpital Femme Mère Enfant, Bron, France.
Unlabelled: Among the 32 items of the Motor Function Measure scale, 3 concern the assessment of hand function on a paper-based support. Their characteristics make it possible to envisage the use of a tablet instead of the original paper-based support for their completion. This would then make it possible to automate the score to reduce intra- and inter-individual variability.
View Article and Find Full Text PDFArch Dermatol Res
January 2025
Department of Dermatology, Medical Research and Clinical Studies Institute, National Research Centre, Giza, Egypt.
Palmar hyperhidrosis is common condition that is challenging to treat. Nonsurgical treatments include topical antiperspirants, iontophoresis, anticholinergic drugs and botulinum toxin injections. To evaluate the safety and efficacy of ablative fractional laser therapy, combined with topically applied botulinum toxin versus its injection for the treatment of hyperhidrosis.
View Article and Find Full Text PDFVet Surg
January 2025
Atlantic Veterinary College, University of Prince Edward Island, Charlottetown, Prince Edward Island, Canada.
Objective: To evaluate the accuracy of ventral slot creation in canine cadavers with a three-dimensional (3D)-printed drill guide compared to the freehand technique.
Study Design: Ex vivo study.
Sample Population: Eight canine cadavers (23.
Musculoskelet Surg
January 2025
Department of Trauma and Orthopaedic Surgery, Barts Health NHS Trust, Royal London Hospital, London, E11BB, England.
3D-printed (3DP) drill guides have demonstrated significant potential to accurately guide pedicle screw insertion in spinal surgery. However, their role in the upper cervical spine is not well established. This review aimed to compare the efficacy and safety of 3DP drill guides to the conventional fluoroscopic-guided free-hand technique for pedicle screw insertion in the upper cervical spine.
View Article and Find Full Text PDFJ Environ Manage
January 2025
Departamento de Ecología y Biodiversidad, Facultad de Ciencias de la Vida, Universidad Andres Bello, Santiago, Chile; Centro de Investigaciones Marinas de Quintay, Universidad Andres Bello, Chile. Electronic address:
The Eastern Boundary Upwelling Systems (EBUS) sustains some of the most productive marine systems on Earth. Within each of these systems, the upwelling process exhibits spatial and temporal variation resulting in marked differences in upwelling intensity and seasonality along extensive coastlines. The study of this variation is well needed, given the magnitude of the services provided by upwelling, and the impending impacts of global warming on EBUS.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!