Objective: Many performance measurement systems are designed to identify differences in the quality provided by health plans or facilities. However, we know little about whether different methods of performance measurement provide similar answers about the quality of care of health care organizations. To examine this question, we used three different measurement approaches to assess quality of care delivered in veteran affairs (VA) facilities.
Data Sources/study Setting: Medical records for 621 patients at 26 facilities in two VA regions.
Study Design: We examined agreements in quality conclusions using: focused explicit (38 measures for six conditions/prevention), global explicit (372 measures for 26 conditions/prevention), and structured implicit review physician-rated care (a single global rating of care for three chronic conditions and overall acute, chronic and preventive care). Trained nurse abstractors and physicians reviewed all medical records. Correlations between scores from the three systems were adjusted for measurement error in each using multilevel regression models.
Results: Intercorrelations of scores were generally moderate to high across all three systems, and rose with adjustment for measurement error. Site-level correlations for prevention and diabetes care were particularly high. For example, adjusted for measurement error at the site level, prevention quality was correlated at 0.89 between the implicit and global systems, 0.67 between implicit and focused, and 0.73 between global and focused systems.
Conclusions: We found moderate to high agreement in quality scores across the three profiling systems for most clinical areas, indicating that all three were measuring a similar construct called "quality." Adjusting for measurement error substantially enhanced our ability to identify this underlying construct.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/j.1475-6773.2007.00730.x | DOI Listing |
Cogn Process
January 2025
Institute of Cognitive Sciences and Technologies (ISTC-CNR), Via Nomentana 56, 00161, Rome, Italy.
Face masks can impact processing a narrative in sign language, affecting several metacognitive dimensions of understanding (i.e., perceived effort, confidence and feeling of understanding).
View Article and Find Full Text PDFEur J Hosp Pharm
January 2025
Department of Pharmacy, Centre Hospitalier Universitaire de Toulouse, Toulouse, France
Purpose: More than 20% of prescription errors in hospitals are due to an incomplete medication history. Medication reconciliation is a solution to decrease unintentional discrepancies between medications taken at home and hospital prescriptions. It is a normalised clinical activity but it is time consuming.
View Article and Find Full Text PDFIntroduction: There is a general impression that patient-based quality control (PBQC) requires a high volume of laboratory results to detect errors effectively. However, internal quality control (IQC) performed infrequently may be associated with increased risk of missed error (i.e.
View Article and Find Full Text PDFComput Biol Med
January 2025
SCOPIA Research Group, University of the Balearic Islands, Dpt. of Mathematics and Computer Science, Crta. Valldemossa, Km 7.5, Palma, E-07122, Spain; Health Research Institute of the Balearic Islands (IdISBa), Palma, E-07122, Spain; Laboratory for Artificial Intelligence Applications at UIB (LAIA@UIB), Palma, E-07122, Spain; Artificial Intelligence Research Institute of the Balearic Islands (IAIB), Palma, E-07122, Spain. Electronic address:
Sickle cell disease causes erythrocytes to become sickle-shaped, affecting their movement in the bloodstream and reducing oxygen delivery. It has a high global prevalence and places a significant burden on healthcare systems, especially in resource-limited regions. Automated classification of sickle cells in blood images is crucial, allowing the specialist to reduce the effort required and avoid errors when quantifying the deformed cells and assessing the severity of a crisis.
View Article and Find Full Text PDFBiomed Phys Eng Express
January 2025
Physics and Applied Mathematics, Pakistan Institute of Engineering and Applied Sciences, Qau, Islamabad, Islamabad, 44000, PAKISTAN.
The current study investigated the geometry, design and solid angle impacts on full energy peak efficiency (FEPE) of NaI(Tl) detectors for a line source. A line source is fabricated using 99mTc solution filled in a borosilicate glass tube of inner diameter 3 mm, tube wall thickness 2.5 mm and length 12.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!