Objectives: To report a novel approach to overcome the problems associated with a short right renal vein harvested by clipping the vein during right laparoscopic donor nephrectomy (RLDN).

Patients And Methods: This prospective study included 32 donors and their recipients; all donors had transperitoneal RLDN. The right renal artery and vein were ligated by Hem-o-lok and titanium clips, which resulted in a very short renal vein (<1.5 cm). When the kidney was positioned inverted in the recipient, the renal vein was placed posteriorly, adjacent to the external iliac vein, making a safe and simple venous anastomosis possible.

Results: All RLDN were completed with no conversion or re-operation. The mean (range) warm ischaemia time was 9.59 (3-17) min and there was no malfunction of the vascular clips on the major vessels. After a mean follow-up of 14 months the recipient survival rate was 97%. Graft function was excellent, with a mean (sd) serum creatinine level of 1.35 (0.31) mg/dL at 3 months after surgery, and there was no renal artery or vein thrombosis in any of the grafts. There were two ureteric complications (6%), i.e. one ureterocutaneous fistula resolved by secondary ureteroureterostomy, and one stricture at the site of ureteric anastomosis, which was managed by ureteroneocystostomy.

Conclusion: The right renal vein obtained by LDN, after clipping the renal vein, is quite short, but by placing the kidney upside-down in the right iliac fossa transplantation is possible with no increased incidence of vascular thrombosis. This simple modification might obviate the need for removing a patch from the inferior vena cava, which is a challenging procedure for laparoscopic surgeons during RLDN.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1464-410X.2007.07134.xDOI Listing

Publication Analysis

Top Keywords

laparoscopic donor
8
donor nephrectomy
8
short renal
8
renal vein
8
nephrectomy inverted
4
inverted kidney
4
kidney transplantation
4
transplantation alternative
4
alternative technique
4
technique objectives
4

Similar Publications

Study Question: Does a human fallopian tube (HFT) organoid model offer a favourable apical environment for human sperm survival and motility?

Summary Answer: After differentiation, the apical compartment of a new HFT organoid model provides a favourable environment for sperm motility, which is better than commercial media.

What Is Known Already: HFTs are the site of major events that are crucial for achieving an ongoing pregnancy, such as gamete survival and competence, fertilization steps, and preimplantation embryo development. In order to better understand the tubal physiology and tubal factors involved in these reproductive functions, and to improve still suboptimal in vitro conditions for gamete preparation and embryo culture during IVF, we sought to develop an HFT organoid model from isolated adult stem cells to allow spermatozoa co-culture in the apical compartment.

View Article and Find Full Text PDF

Background: Postoperative pain remains a significant problem in patients undergoing donor nephrectomy despite reduced tissue trauma following laparoscopic living donor nephrectomy (LLDN). Inadequately treated pain leads to physiological and psychological consequences, including chronic neuropathic pain.

Materials And Methods: This randomized controlled double-blinded trial was conducted in sixty-nine (n = 69) participants who underwent LLDN under general anesthesia.

View Article and Find Full Text PDF

Early outcomes of robotic vs open living donor right hepatectomy in a US Center.

Surg Endosc

January 2025

Division of Transplant Surgery, Department of Surgery, Hume- Lee Transplant Center, Virginia Commonwealth University School of Medicine, Richmond, VA, USA.

Background: Robotic living donor hepatectomy offers potential advantages but has been limited to high-volume centers, primarily in Asia and the Middle East. We report our experience establishing a robotic living donor right hepatectomy program in a U.S.

View Article and Find Full Text PDF

BACKGROUND Transplant lithiasis may be rare but poses significant risk to the renal graft function of the recipient. Immediate management is necessitated upon first detection, to prevent further complications. CASE REPORT We report 2 cases of transplant lithiasis that were not treated immediately upon first detection.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!