It has been shown that cat soleus (SOL) forces remain nearly constant despite increases in electromyography (EMG) activity for increasing speeds of locomotion, while medial gastrocnemius (MG) forces and EMG activity increase in parallel. Furthermore, during jumping, average cat SOL forces decrease, while average EMG activity increases dramatically compared with walking conditions. Finally, during rapid paw-shake movements, SOL forces and EMG activities are nearly zero. Based on these results, we hypothesized that the SOL is deactivated, despite ankle extensor requirements, if the contractile conditions limit SOL force potential severely. The purposes of this study were to (i) investigate SOL EMG activity and force as a function of its contractile conditions during jumping, (ii) test whether SOL EMG activity is associated with SOL contractile conditions, and (iii) determine the functional implications of SOL EMG activity during jumping. It was found that the SOL was prematurely deactivated in two distinct phases during the propulsive phase of jumping, in which shortening speeds approached or even exceeded the maximal speed of muscle shortening. We concluded that the SOL was prematurely deactivated to save energy because its mechanical work output approached zero, and speculated that the first phase of deactivation might be caused by a decrease in group Ia firing associated with active shortening and the second by a pre-programmed response inherent to the central pattern generator.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2607386 | PMC |
http://dx.doi.org/10.1098/rsif.2007.1158 | DOI Listing |
Muscle Nerve
January 2025
International Collaboration on Repair Discoveries (ICORD), Vancouver, British Columbia, Canada.
Introduction/aims: Upper limb paralysis is arguably the most limiting consequence of cervical spinal cord injury (cSCI). There is limited knowledge regarding the early structural changes of muscles implicated in grasp/pinch function and upper extremity nerve transfer surgeries. We evaluated: (1) muscle size and echo intensity (EI) in subacute cSCI (2-6 months) and (2) the influence of lower motor neuron (LMN) damage on these ultrasound parameters.
View Article and Find Full Text PDFJ Neurophysiol
February 2025
Breathing Research and Therapeutics Center, Department of Physical Therapy, University of Florida, Gainesville, Florida, United States.
We present a case report of a 42-year-old female with post-West Nile virus meningoencephalitis who exhibited unique, long-latency diaphragm potentials evoked by transcranial and cervical magnetic stimulation after exposure to acute intermittent hypoxia (AIH). The subject was recruited for a study investigating AIH effects on respiratory motor function in healthy individuals. She had contracted West Nile virus infection 5 years before assessment that resulted in hospitalization and persistent allodynia but was not reported to the research team.
View Article and Find Full Text PDFNeurol Int
January 2025
Laboratório de Marcha, Centro de Medicina de Reabilitação de Alcoitão, 2649-506 Alcabideche, Portugal.
Background/objectives: Post-stroke hemiparetic gait often presents with asymmetric patterns to compensate for stability deficits. This study examines gait differences in chronic stroke patients with spastic hemiparesis based on initial foot contact type-forefoot versus rearfoot.
Methods: Thirty-four independently walking spastic hemiparetic patients were retrospectively analyzed.
Metabolites
January 2025
Department of Animal and Dairy Science, University of Georgia, Athens, GA 30602, USA.
When measuring real-time in vivo muscle fatigue with electromyography (), data collection can be compromised by premature sensor removal or environmental noise; therefore, the objective of this study was to develop a postmortem in vivo methodology to induce muscle fatigue and measure it using EMG. Barrows ( = 20) were stratified by weight and randomly allocated into one of two treatments. The treatments consisted of barrows being subjected to a hog electric stunner super-contraction cycle () or not () postmortem.
View Article and Find Full Text PDFBiomimetics (Basel)
January 2025
School of Mechanical Engineering, Jiangsu University of Technology, Changzhou 213001, China.
To reduce hip joint muscles' activation during walking with an active hip exoskeleton. Few studies examine the optimal active assistance timing of the hip exoskeleton based on muscle activation characteristics. Sixteen gender-balanced healthy adults (mean age 28.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!