Background: Our prior studies suggest that mitral annular septal-lateral (SL) diameter is the chief determinant of "Alfieri stitch" tension, but hemodynamic parameters may also play a role. We approximated the central edge of the mitral leaflets with a miniature force transducer to measure tension (T) at the leaflet approximation point during inotropic and chronotropic stimulation.
Methods And Results: Eight sheep were studied under open-chest conditions immediately after surgical placement of a miniature force transducer to approximate the leaflets and implantation of radiopaque markers on the LV and mitral annulus (MA). Chronotropic stimulation was induced with atrial pacing at 130 minutes(-1) (n=5) whereas inotropic state was increased with i.v. CaCl2 bolus (n=8). Hemodynamic data, stitch tension, and 3-D marker coordinates were obtained throughout the cardiac cycle before and during each intervention. Peak stitch tension (T(MAX)) under all conditions was observed in diastole and temporally correlated with peak annular SL (SL(MAX)) size. Atrial pacing did not change peak transducer tension or annular size. Calcium infusion also did not alter peak transducer tension (0.29+/-0.11 versus 0.32+/-0.10 N; P=NS) and only slightly reduced SL dimension (29.9+/-3.3 versus 29.3+/-3.5 mm; P<0.05).
Conclusion: Isolated increase in heart rate or inotropic state did not alter peak stitch tension whereas enhanced contractile state decreased SL diameter minimally. These data, combined with those from our previous study, suggest that geometric (SL diameter) rather than hemodynamic parameters are the main determinants of "Alfieri stitch" tension. This implies that any interventional or surgical edge-to-edge repair performed without concomitant annular reduction to limit the SL dimension could expose the leaflet junction to forces which could limit repair durability.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1161/CIRCULATIONAHA.106.680801 | DOI Listing |
BMC Musculoskelet Disord
December 2024
Department of Orthopedics, Trauma and Plastic Surgery, University of Leipzig, Leipzig, Germany.
Background: Ruptures of the anterior cruciate ligament (ACL) are common injuries. Reconstruction using autologous grafts is recommended to prevent further damage and functional impairment. Grafts are usually prepared with stabilizing sutures.
View Article and Find Full Text PDFArthroscopy
December 2024
Department of Medical Engineering and Physics, Centre for Implant Technology and Retrieval Analysis, Royal Perth Hospital, Perth, Australia.
Purpose: To assess the variability in graft biomechanical properties of an acellular human dermal matrix patch.
Methods: A total of 22 strips obtained from 6 separate graft specimens (AlloPatch HD) were tested. Load elongation properties after cyclic loading, including ultimate load at break, energy at break, and extension at break, were tested and compared by graft thickness.
Front Public Health
November 2024
Nantes Université, CHU Nantes, Service de Gynécologie-Obstétrique, Mouvement - Interactions - Performance, Nantes, France.
Can Urol Assoc J
November 2024
Department of Urologic Sciences, University of British Columbia, Vancouver, BC, Canada.
JBJS Essent Surg Tech
September 2024
Department of Orthopaedics, University of Utah, Salt Lake City, Utah.