A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Determination of vigabatrin in human plasma by means of CE with LIF detection. | LitMetric

Determination of vigabatrin in human plasma by means of CE with LIF detection.

Electrophoresis

Pharmaco-Toxicological Analysis Laboratory, Department of Pharmaceutical Sciences, Alma Mater Studiorum-University of Bologna, Via Belmeloro 6, I-40126 Bologna, Italy.

Published: October 2007

A method has been developed for the quantitation of the antiepileptic drug vigabatrin (VGB) in human plasma. It is based on CE with LIF detection. The effect of the pH of the buffer and of N-methylglucamine (GLC) as BGE constituent was investigated. The final BGE consisted of 50 mM borate buffer, pH 9.0, with 100 mM GLC and enabled separation within 12 min at 20 kV voltage. An SPE procedure was used for the pretreatment of biological samples, based on mixed-mode lipophilic-cation exchange cartridges, followed by a derivatization step with 6-carboxyfluorescein-N-succinimidyl ester (CFSE). Fluorescence was excited by an Ar-ion laser (lambda(exc) = 488 nm). Linearity was observed in the 10-120 microg/mL plasma concentration range. Extraction yield was >96%, precision (expressed as RSD) <6.7% and accuracy (recovery) was between 97.0 and 101.6%. The method has been successfully applied to the analysis of VGB in plasma of epileptic patients undergoing therapy with the drug.

Download full-text PDF

Source
http://dx.doi.org/10.1002/elps.200700139DOI Listing

Publication Analysis

Top Keywords

human plasma
8
lif detection
8
determination vigabatrin
4
vigabatrin human
4
plasma lif
4
detection method
4
method developed
4
developed quantitation
4
quantitation antiepileptic
4
antiepileptic drug
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!