A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Reliability of a new instrument for measuring plantarflexor muscle strength. | LitMetric

Objectives: To test the reliability of a new muscle strength testing instrument (the Strength Measuring Chair [SMC]) designed to quantify isometric strength in the lower extremities, and to determine the agreement between the SMC and an isokinetic dynamometer (Biodex).

Design: Isometric strength tests were performed in plantarflexors with 2 different knee positions (60 degrees, 30 degrees). Measurements were taken at 3 different sessions.

Setting: Strength testing laboratory.

Participants: Twenty-three able-bodied adults and 15 able-bodied children.

Interventions: Not applicable.

Main Outcome Measure: Isometric plantarflexor strength.

Results: The reliability of isometric strength measurements of plantarflexors taken in the SMC was excellent for both the adult and children groups (intraclass correlation coefficient range, .84-.87). A Bland-Altman 95% limit of agreement test showed no systematic variation in 3 of the 4 SMC test observations; systematic variation was only observed in the adult group at a knee position of 30 degrees. There was no systematic difference in the adult group between the SMC and the isokinetic dynamometer, but there was a systematic variation in the children's group.

Conclusions: The SMC reliably measured isometric plantarflexor strength in the tested populations.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.apmr.2007.05.028DOI Listing

Publication Analysis

Top Keywords

isometric strength
12
systematic variation
12
strength
8
muscle strength
8
strength testing
8
smc isokinetic
8
isokinetic dynamometer
8
isometric plantarflexor
8
adult group
8
isometric
5