Background: Using an endoscopic ultrasound (EUS) miniprobe, even highly stenotic esophageal cancers precluding the passage of a conventional probe can be examined without prior dilatation.
Objective: To assess: (1) staging accuracy of conventional EUS probe and miniprobe, (2) variables influencing staging accuracy, (3) endoscopic features predicting tumor stage.
Methods: Ninety-seven consecutive patients with esophageal cancer undergoing complete surgical resection were included. Preoperative EUS was performed using a conventional probe in nonstenotic tumors and a miniprobe in stenotic tumors. Accuracy of EUS for T and N stages was compared to pathohistological staging.
Results: Overall EUS staging accuracy was 73.2% for T stage and 74.2% for N stage. It was similar for the miniprobe used in stenotic tumors vs the conventional probe used in nonstenotic tumors. Based on EUS, 84.5% of the patients would have been assigned to the appropriate therapy protocol (primary surgery vs neoadjuvant therapy). Endoscopic tumor features had no influence on staging accuracy. Tumor length >5 cm predicted advanced T and nodal positive stages.
Conclusions: The miniprobe allows adequate EUS staging of stenotic esophageal tumors precluding the passage of a conventional probe. Therefore, dilatation therapy of stenotic cancers to conduct conventional EUS should be avoided.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s11605-007-0300-2 | DOI Listing |
ACS Sens
January 2025
National Engineering Research Center of Fiber Optic Sensing Technology and Networks, Wuhan University of Technology, Wuhan 430070, China.
This paper presents a compact all-fiber multicomponent gas Raman probe using a dual-fiber architecture within a platinum-coated capillary. The probe eliminates the need for conventional optical components like filters and dichroic mirrors by strategically employing metal coating on the excitation fiber's surface to suppress interference signals. A detailed analysis of the silica Raman signal and fluorescence propagation within the system facilitated this design.
View Article and Find Full Text PDFEvid Based Dent
January 2025
All India Institute of Medical Sciences, Bathinda, Punjab, India.
Design: The study is a prospective, double-blinded randomised control trial that compares the mineral trioxide aggregate (MTA) and Biodentine as the pulp space barrier material after induction of a periapical blood clot by over-instrumentation for endodontic regeneration in single-rooted mature permanent anterior tooth (closed apex) with apical periodontitis (periapical pathology of more than 3 mm) and having necrosed pulp. A total of 36 patients were included in the study and after randomisation were allocated equally to both the groups out of which 31 patients returned for follow-up over an 18-month period. The treatment protocol consisted of two separate appointments.
View Article and Find Full Text PDFNat Commun
January 2025
State Key Laboratory of Urban Water Resource and Environment, School of Environment, Harbin Institute of Technology, Harbin, 150090, PR China.
Heterotrophic denitrifiers play crucial roles in global carbon and nitrogen cycling. However, their inability to oxidize sulfide renders them vulnerable to this toxic molecule, which inhibits the key enzymatic reaction responsible for reducing nitrous oxide (NO), thereby raising greenhouse gas emissions. Here, we applied microcosm incubations, community-isotope-corrected DNA stable-isotope probing, and metagenomics to characterize a cohort of heterotrophic denitrifiers in estuarine sediments that thrive by coupling sulfur oxidation with denitrification through chemolithoheterotrophic metabolism.
View Article and Find Full Text PDFAnal Chem
January 2025
State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Jilin, Changchun 130022, China.
Lateral flow immunochromatography (LFIA) with gold nanoparticles (AuNPs) is widely used in the biomedical field as a rapid and simple in vitro detection technique. However, the conventional AuNP-LFIA has limitations in sensitivity and detection range. In this study, nonprecious metal iron-based bimetallic FeWO nanomaterials with convenient and excellent enzyme-mimetic catalytic activities were synthesized by a one-pot hydrothermal method.
View Article and Find Full Text PDFBioanalysis
January 2025
College of Chemistry, Beijing University of Chemical Technology, Beijing, China.
Ultrasmall and highly fluorescent gold nanoclusters (Au NCs) have been widely used for the construction of sensing and imaging platforms. Specifically, through a combination of surface functionalization and spectral analysis and/or imaging techniques, effective intracellular detection and imaging are realized. In this review, we summarize the recently adopted intracellular analysis and imaging events with Au NCs-based probes.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!