Objectives: Thermodilution (TD) is the "gold standard method" for hemodynamic monitoring. Some parameters can be measured by Oesophageal Doppler (OD), which is simpler and less invasive. To evaluate the accuracy of OD, we compared this method with TD in measurement of cardiac output (CO).
Methods: One hundred and ninety two simultaneous measurements were made in 10 patients (5 male and 5 female) with different clinical situations, 8 with sepsis using vasoactive drugs and 2 monitored for laryngectomy and liver transplantation. Measurements were taken during 4 hours at 30 minute intervals. The two oesophageal dopplers used DeltexR and ArrowR, were introduced between 35 and 45 cm from the nose and located at the point of largest diameter of the descending aorta. In TD, we used the pulmonary artery catheter (Swan Ganz BaxterR) and the DX- 2001 monitorR positioning was confirmed with support of radiology and of pressures curves. Measurements of CO carried out by means of TD were achieved using an iced saline solution considering the mean of four measurements with less than a 5% difference. The statistical method used was the Bland-Altman scatter plot and dispersion graphic.
Results: No statistically significant difference was found between the two methods for hemodyamic measurement with a correlation coefficient of 0.8 for CO (Deltex DopplerR and Baxter Swan GanzR) and a correlation coefficient of 0.99 for CO (Arrow DopplerR and Baxter Swan GanzR).
Conclusion: Homodynamic measurements with OD have the same accuracy as those with TD and were easily obtained in the 10 patients.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1590/s0104-42302007000400022 | DOI Listing |
Prosthet Orthot Int
January 2025
School of Physical Education and Physiotherapy, Federal University of Uberlândia (UFU), Minas Gerais, Brazil.
Background: Preferred walking speed (PWS), maximal walking speed (MWS), and walking speed reserve (WSR)-the difference between MWS and PWS-can be easily obtained from the 10-m walk test (10MWT) to assess walking ability and function. However, their test-retest reliability has not been determined in persons with unilateral lower-limb amputation (LLA).
Objectives: To determine the reliability of the PWS, MWS, and WSR obtained from the 10MWT in persons with LLA.
Purpose: To describe relationships among grit, spirituality, and hope in women Veterans ( = 80).
Method: A descriptive, correlational design was used. Study variables were measured with the Short Grit Scale, Daily Spiritual Experience Scale, and Hope Scale.
Environ Monit Assess
January 2025
School of Energy and Power Engineering, Xihua University, No. 9999 Hongguang Street, Chengdu, 610039, Sichuan Province, China.
Analysis of crop water requirement and its influencing factors are important for optimal allocation of water resources. However, research on variations of climatic factors and their contribution to wheat water requirement in Xinjiang is insufficient. In our study, daily meteorological data during 1961‒2017 in Xinjiang was collected.
View Article and Find Full Text PDFOral Maxillofac Surg
January 2025
Department of Restorative, School of Dentistry, Dental Research Center, Hamadan University of Medical Sciences, Pajouhesh Square, Hamadan, 6517838736, Iran.
Purpose: The harmony between the lips and the chin is an essential parameter in facial esthetics, and the mentolabial sulcus (MLS) represents the level of this harmony. This study aimed to assess the effect of MLS depth on facial profile attractiveness in long-face, short-face, and normal-face Iranian female individuals.
Methods: An observational study with a questionnaire was conducted, and a profile photograph of an Iranian female with class I occlusion was altered to create long-face, normal-face and short-face profiles with MLS depth ranging from 1 to 12 mm.
Eur J Sport Sci
February 2025
Faculty of Education, Psychology and Sport Sciences, COIDESO, University of Huelva, Huelva, Spain.
The present study aimed to explore the validity and inter-device reliability of a novel artificial intelligence app (Asstrapp) for real-time measurement of the traditional (tra505) and modified-505 (mod505) change of direction (COD) tests. Twenty-five male Sports Science students (age, 23.5 ± 3.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!