Synchrotron radiation high-energy X-ray fluorescence (SR-XRF) analysis utilizing 75.5keV X-ray radiation from beam-line BL37XU at Super Photon Ring 8GeV (SPring-8), a third-generation synchrotron facility, was found to have advantages for forensic discrimination of glass samples. The lower limits of detection (LLD) for calibration curves were at the picogram level for Ba, Ce, and Sm and at the 10pg level for Sr, Zr, Sn, and Hf. The spectrum of NIST SRM 612 glass reference material demonstrated K-line peaks of 31 elements including rare-earth elements, and the relative standard deviations (R.S.D.) of all the measured elements except Ca were less than 9.7%. Fragments of collected sheet glass were used as samples for investigating the application of this technique to forensic analysis. Several trace elements such as Pb, Rb, Sr, Zr, La, Ce, and Hf were detected in the spectra of the samples, and these elements could be used as indexes to characterize the glass samples. But the "lower limits of detection (LLD)" of each element were not examined enough. In this report, these limits by synchrotron radiation X-ray spectrometry were clarified. By these results, this technique should provide an effective approach to the nondestructive discrimination of small glass fragments in the field of forensic science.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.forsciint.2007.07.001 | DOI Listing |
Pol J Vet Sci
June 2024
Department of Surgery, Faculty of Veterinary Medicine, University of Siirt, Kezer Campus, Veysel Karani District, University Street, Siirt/Türkiye.
In this study, a total of 32 Trueperella pyogenes strains isolated from different disease specimens in cattle, sheep and goats were examined. Antimicrobial susceptibility of the isolates to 10 antimicrobials were determined using the E-test method and MIC values of the antimicrobials were investigated. The genes that play a role in the antimicrobial resistance or virulence of T.
View Article and Find Full Text PDFPol J Vet Sci
December 2024
Anhui Province Key Laboratory of Veterinary Pathobiology and Disease Control, College of Animal Science and Technology, Anhui Agricultural University, Hefei, Anhui 230036, PR China. Email:
The aim of this study was to develop a rapid, sensitive and highly specific TaqMan quantitative real-time polymerase chain reaction PCR (qPCR) assay for porcine circovirus-like virus (PCLV). The primers and probe were designed based on the conserved regions of the PCLV ORF4 gene. The assay has a good detection performance (y=-3.
View Article and Find Full Text PDFPol J Vet Sci
December 2024
School of Biotechnology and Food Engineering, Anyang Institute of Technology, Anyang, China.
Pseudorabies virus (PRV) is one of the most important infectious diseases which leads to significant economic losses in the global swine industry. The gE-deleted vaccine is widely used to prevent susceptible pigs from PRV infection. There is no report of the differentiation of PRV wild strain and vaccine strain by recombinase polymerase amplification (RPA) coupled with a lateral flow dipstick (LFD) method.
View Article and Find Full Text PDFFront Biosci (Schol Ed)
December 2024
Department of Molecular, Cell and Cancer Biology, University of Massachusetts Chan Medical School, Worcester, MA 01605, USA.
Background: Alternative cleavage and polyadenylation (APA) is a crucial post-transcriptional gene regulation mechanism that regulates gene expression in eukaryotes by increasing the diversity and complexity of both the transcriptome and proteome. Despite the development of more than a dozen experimental methods over the last decade to identify and quantify APA events, widespread adoption of these methods has been limited by technical, financial, and time constraints. Consequently, APA remains poorly understood in most eukaryotes.
View Article and Find Full Text PDFCJC Open
December 2024
Division of Cardiology, University of British Columbia, Vancouver, British Columbia, Canada.
Background: Atrial fibrillation (AF) is the most common cardiac arrhythmia. Given its often-paroxysmal nature, screening at a single time point, using a 12-lead electrocardiogram (ECG) or a Holter monitor, has limited benefit. The AliveCor KardiaMobile device is a validated ECG recorder that can be used for patient-directed arrhythmia diagnosis and symptom-rhythm correlation.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!