A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Sutureless Transconjunctival 20 Gauge pars plana Vitrectomy. | LitMetric

Purpose: Sutureless Transconjunctival 20 Gauge Vitrectomy (20G STV) is a technique that reduces the operating time and the post-operative inflammation.

Patients And Method: Eighty-four eyes underwent this new technique. Conjunctival diathermy over the ports before sclerostomy produced adhesions adequate to stop transoperative conjunctival chemosis. The MVR blade introduced into the conjunctiva-sclera in a bevelled direction. The tunnel incision that was created left without a suture at the end of the operation.

Results: Three patients (3,5%) had hypotony (2-6 mmHg) on day 1 that was normalized 3 days later. Two of them had a bleb formation and the rest a very minor leakage through a flat conjunctiva. No other serious complications occurred as a result of this novel transconjunctival approach. Also there were no differences in visual acuity, intraocular pressure, redetachments, or inflammations between the patients who underwent this technique and the patients having the conventional 20-gauge pars plana technique.

Conclusion: 20G STV is a safe and practical technique for the full spectrum of vitreoretinal surgery. It makes the surgery quicker and is well tolerated by patients.

Download full-text PDF

Source
http://dx.doi.org/10.1080/08820530701501170DOI Listing

Publication Analysis

Top Keywords

sutureless transconjunctival
8
transconjunctival gauge
8
pars plana
8
20g stv
8
underwent technique
8
gauge pars
4
plana vitrectomy
4
vitrectomy purpose
4
purpose sutureless
4
gauge vitrectomy
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!