When a nebulizer is evaluated by the Andersen Cascade Impactor (ACI), the flow rate is generally maintained at 28.3 L/min, as recommended by the manufacturer. However, the nebulizer flow rate that a patient inhales is only around 18 L/min. Because the drive flow of a nebulizer is approximately 6-8 L/min, the nebulized drug is mixed with outside air when delivered. Evaluating impactor performance at the 28.3 L/min flow rate is less than ideal because an additional 10 L/min of outside air is mixed with the drug, thereby affecting the drug size distribution and dose before inhalation and deposition in the human lung. In this study we operated the ACI at an 18.0 L/min flow rate to test whether the effect of the changing ambient humidity was being exaggerated by the 28.3 L/min flow rate. The study was carried out at three different relative humidity levels and two different impactor flow rates with four commercially available nebulizers. The mass median aerodynamic diameter (MMAD) and the geometric standard deviation (GSD) of the droplets were found to increase when the impactor was operated at a flow rate of 18 L/min compared to that of 28.3 L/min. The higher MMAD and GSD could cause the patient to inhale less of the drug than expected if the nebulizer was evaluated by the ACI at the operating flow rate of 28.3 L/min.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1080/10837450701366937 | DOI Listing |
Biomed Chromatogr
January 2025
Drug Metabolism and Pharmacokinetics, Laxai Life Sciences Pvt. Ltd, Hyderabad, India.
A highly sensitive and rapid LC-MS/MS method was developed and validated for the quantification of dexamethasone in rat plasma and brain tissue. Protein precipitation method was used for sample preparation. The separation of dexamethasone and the IS (labetalol) was achieved on an Atlantis dC column using an isocratic mobile phase (10 mM ammonium formate and acetonitrile, 25/75, v/v) delivered at 0.
View Article and Find Full Text PDFMol Cell Probes
December 2024
Farhikhtegan Medical Convergence Sciences Research Center, Farhikhtegan Hospital Tehran Medical Sciences, Islamic Azad University, Tehran, Iran; Department of Genetics, Faculty of Advanced Science and Technology, Tehran Medical Sciences, Islamic Azad University, Tehran, Iran. Electronic address:
Background: breast cancer-associated fibroblast (CAF) is linked to metastasis and is poor for breast cancer prognosis. Since Clostridium Toxin A (Botox-A) had represented a cytotoxic effect on fibroblasts, this study aims to assess Botox-A cytotoxicity in both normal fibroblasts and exosome-induced CAFs.
Material And Method: the serum exosomes of 40 BC patients and 30 healthy individuals were isolated and lncRNA H19 (lnch19) levels were assessed by qRT-PCR method.
J Reprod Immunol
December 2024
School of Medical and Life Sciences/Reproductive &Women-Children Hospital, Chengdu University of Traditional Chinese Medicine, No.1166 Liutai Avenue, Wenjiang District, Chengdu, Sichuan Province 611137, China; Chengdu Fifth People's Hospital, Affiliated Fifth People's Hospital of Chengdu University of Traditional Chinese Medicine. Electronic address:
Backgrounds: Recent studies have found Several lncRNAs were proved differential expression in diminished ovarian reserve (DOR) patients, however, the mechanism of DOR caused by lncRNAs is still largely unclear.
Methods: High throughput sequencing was performed in ovarian GCs extracted from women with normal ovarian function and women with DOR. Bioinformation analysis was used to analyze the sequencing data and identify the differential expression of lncRNAs.
Biosens Bioelectron
December 2024
Nanobiointeractions&Nanodiagnostics, Istituto Italiano di Tecnologia (IIT), Via Morego, 30, 16163, Genova, Italy. Electronic address:
Lateral flow assays (LFA) are widely adopted in point-of-care diagnostics across a spectrum of applications, due to their simplicity of use and cost-effectiveness. However, in complex biological matrices (e.g.
View Article and Find Full Text PDFJ Med Ultrason (2001)
December 2024
Department of Internal Medicine, Kuma Hospital, Kobe, Hyogo, 650-0011, Japan.
Purpose: Parathyroid lipoadenomas are difficult to recognize preoperatively; hence, they may remain undetected. Difficulty in recognition is thought to be due to the adipocytes present in the tumor. This study aimed to clarify the impact of adipocytes as a component of parathyroid adenomas on ultrasound evaluation.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!