Interferometric near-field optical microscopy achieving a resolution of 10 angstroms is demonstrated. The scattered electric field variation caused by a vibrating probe tip in close proximity to a sample surface is measured by encoding it as a modulation in the optical phase of one arm of an interferometer. Unlike in regular near-field optical microscopes, where the contrast results from a weak source (or aperture) dipole interacting with the polarizability of the sample, the present form of imaging relies on a fundamentally different contrast mechanism: sensing the dipole-dipole coupling of two externally driven dipoles (the tip and sample dipoles) as their spacing is modulated.

Download full-text PDF

Source
http://dx.doi.org/10.1126/science.269.5227.1083DOI Listing

Publication Analysis

Top Keywords

near-field optical
8
scanning interferometric
4
interferometric apertureless
4
apertureless microscopy
4
optical
4
microscopy optical
4
optical imaging
4
imaging angstrom
4
angstrom resolution
4
resolution interferometric
4

Similar Publications

A Review of Cascaded Metasurfaces for Advanced Integrated Devices.

Micromachines (Basel)

December 2024

State Key Laboratory of Precision Measuring Technology & Instruments, Tianjin University, Tianjin 300072, China.

This paper reviews the field of cascaded metasurfaces, which are advanced optical devices formed by stacking or serially arranging multiple metasurface layers. These structures leverage near-field and far-field electromagnetic (EM) coupling mechanisms to enhance functionalities beyond single-layer metasurfaces. This review comprehensively discusses the physical principles, design methodologies, and applications of cascaded metasurfaces, focusing on both static and dynamic configurations.

View Article and Find Full Text PDF

As one of the typical applications of metamaterials, the invisibility cloak has raised vast research interests. After many years' research efforts, the invisibility cloak has extended its applicability from optics and acoustics to electrostatics and thermal diffusion. One scientific challenge that has significantly restricted the practical application of the invisibility cloak is the strong background dependence, that is, all passive cloaking devices realized thus far are unable to resist variation in the background refractive index.

View Article and Find Full Text PDF

Detecting electromagnetic radiation scattered from a tip-sample junction has enabled overcoming the diffraction limit and started the flourishing field of polariton nanoimaging. However, most techniques only resolve amplitude and relative phase of the scattered radiation. Here, we utilize field-resolved detection of ultrashort scattered pulses to map the dynamics of surface polaritons in both space and time.

View Article and Find Full Text PDF

Nano FTIR spectroscopy of liquid water in the -OH stretching region.

Spectrochim Acta A Mol Biomol Spectrosc

December 2024

Department of Chemistry, KTH Royal Institute of Technology, Teknikringen 29, SE-100 44 Stockholm, Sweden. Electronic address:

Nano-FTIR spectroscopy is a technique where atomic force microscopy (AFM) and infrared (IR) spectroscopy are combined to obtain chemical information with a lateral resolution of some tens of nm. It has been used to study numerous solid surfaces and recently also liquids including water have been examined by separating the liquid from the AFM tip by a thin lid. However, although the water stretching vibrations are significantly more intense than the bending vibration in conventional IR spectroscopy, only the bending vibration has been observed in nano-FTIR spectroscopy so far.

View Article and Find Full Text PDF

Mesoporous silica nanoparticles (MSNPs) are promising nanomedicine vehicles due to their biocompatibility and ability to carry large cargoes. It is critical in nanomedicine development to be able to map their uptake in cells, including distinguishing surface associated MSNPs from those that are embedded or internalized into cells. Conventional nanoscale imaging techniques, such as electron and fluorescence microscopies, however, generally require the use of stains and labels to image both the biological material and the nanomedicines, which can interfere with the biological processes at play.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!