Visual-evoked potentials (VEPs) were recorded from the surface of the optic tectum of the freshwater turtle, Pseudemys scripta elegans, in response to phase reversal of square-wave gratings of different spatial frequency and contrast. The refractive state of a group of 12 turtles in air was assessed from VEPs by placing trial lenses in front of the eye. The group mean refraction did not differ significantly from emmetropia, as compared to 4.8 diopters of hyperopia when refracted retinoscopically. The difference was explained by the retinoscopic reflex originating from the interface between vitreous humor and retina. Peak VEP amplitude was approximately linear with log grating contrast; extrapolation to zero VEP amplitude yielded contrast thresholds as low as 1%. High spatial-frequency cutoffs ranged from 4.4-9.9 cycle/deg in different animals, the highest values corresponding to the intercone spacing in the area centralis and to behavioral measures of acuity in a related species.

Download full-text PDF

Source
http://dx.doi.org/10.1017/s0952523800010403DOI Listing

Publication Analysis

Top Keywords

refractive state
8
freshwater turtle
8
turtle pseudemys
8
pseudemys scripta
8
scripta elegans
8
visual-evoked potentials
8
vep amplitude
8
contrast
4
state contrast
4
contrast sensitivity
4

Similar Publications

To investigate the pattern and threshold of physiological growth, defining as axial length (AL) elongation that results in little refraction progression, among Chinese children and teenagers, a total of 916 children aged between 7 and 18 years from a 6-year longitudinal cohort study were included for analysis. Ocular biometry, cycloplegic refraction and demographic data were obtained annually. Physiological growth was calculated based on myopic progression and Gullstrand eye model, respectively.

View Article and Find Full Text PDF

Purpose: To compare the efficiency of peristaltic vs venturi vacuum platforms when applied to the femtosecond treated cataract.

Setting: Outpatient Eye Center, Mercy Health System, Springfield, MO, USA.

Design: This is a prospective randomized controlled trial of 111 patients with moderate nuclear sclerosis scheduled for bilateral routine laser cataract surgery (clinicaltrials.

View Article and Find Full Text PDF

Analysis of Refractive Index Sensing Properties of a Hybrid Hollow Cylindrical Tetramer Array.

Nanomaterials (Basel)

January 2025

Xinjiang Key Laboratory for Luminescence Minerals and Optical Functional Materials, School of Physics and Electronic Engineering, Xinjiang Normal University, Urumqi 830054, China.

In recent years, metal surface plasmon resonance sensors and dielectric guided-mode resonance sensors have attracted the attention of researchers. Metal sensors are sensitive to environmental disturbances but have high optical losses, while dielectric sensors have low losses but limited sensitivity. To overcome these limitations, hybrid resonance sensors that combine the advantages of metal and dielectric were proposed to achieve a high sensitivity and a high factor at the same time.

View Article and Find Full Text PDF

Sensing light's polarization and wavefront direction enables surface curvature assessment, material identification, shadow differentiation, and improved image quality in turbid environments. Traditional polarization cameras utilize multiple sensor measurements per pixel and polarization-filtering optics, which result in reduced image resolution. We propose a nanophotonic pipeline that enables compressive sensing and reduces the sampling requirements with a low-refractive-index, self-assembled optical encoder.

View Article and Find Full Text PDF

Anti-Scattering Perovskite Scintillator Arrays for High-Resolution Computed Tomography Imaging.

Adv Mater

January 2025

State Key Laboratory of Supramolecular Structure and Materials, College of Chemistry, Jilin University, Changchun, 130012, P. R. China.

Computed tomography (CT) imaging has emerge as an effective medical diagnostic technique due to its rapid and 3D imaging capabilities, often employing indirect imaging methods through scintillator materials. Arraying scintillators that can confine light scattering to enable high-resolution CT imaging remains an area of ongoing exploration for emerging perovskite scintillators. Here an anti-scattering cesium lead bromide (CsPbBr) scintillator array embedded within a polyurethane acrylate matrix for CT imaging using a cost-effective solution-processed method is reported.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!