Silicone glue coated stainless steel wire for solid phase microextraction.

Anal Chim Acta

Department of Analytical and Environmental Chemistry, Vilnius University, Naugarduko 24, LT-03225 Vilnius, Lithuania.

Published: June 2006

A new solid phase microextraction (SPME) fiber based on high-temperature silicone glue coated on a stainless steel wire is presented. The fiber coating can be prepared easily in a few minutes, it is mechanically stable and exhibits relatively high thermal stability (up to 260 degrees C). The extraction properties of the fiber to benzene, toluene, ethylbenzene, and xylenes (BTEX) were examined using both direct and headspace SPME modes coupled to gas chromatography-flame ionization detection. The effects of the extraction and desorption parameters including extraction and desorption time, sampling and desorption temperature, and ionic strength on the extraction/desorption efficiency have been studied. For both headspace and direct SPME the calibration graphs were linear in the concentration range from 0.5 microg L(-1) to 10 mg L(-1) (R2>0.996) and detection limits ranged from 0.07 to 0.24 microg L(-1). Single fiber repeatability and fiber-to-fiber reproducibility were less than 6.8 and 21.5%, respectively. Finally, headspace SPME was applied to determine BTEX in petrol station waste waters with spiked recoveries in the range of 89.7-105.2%.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.aca.2006.04.035DOI Listing

Publication Analysis

Top Keywords

silicone glue
8
glue coated
8
coated stainless
8
stainless steel
8
steel wire
8
solid phase
8
phase microextraction
8
headspace spme
8
extraction desorption
8
microg l-1
8

Similar Publications

Objective: Therefore, this study aimed to evaluate the maximum displacement resistance of silicone samples adhered to human skin using different adhesives. For this purpose, colorless silicone samples (A-4530-HCRA Silicone Gum HCR) pigmented with Functional Intrinsic II Silicone Coloring System were made and distributed into five groups (1. SA specific adhesive for maxillofacial prostheses: Drying Adhesive; 2.

View Article and Find Full Text PDF

Retinal graft dislocation managed by repeat autologous retinal transplant for refractory macular hole.

BMJ Case Rep

January 2025

Smt. Kanuri Santhamma Centre for Vitreo Retinal Diseases, Anant Bajaj Retina Institute, LV Prasad Eye Institute, Hyderabad, Telangana, India

A septuagenarian man presented with a visual acuity of hand motions and a large refractory macular hole (MH). We performed an autologous retinal transplant (ART) and covered the graft with fibrin glue without any endotamponade. The autograft was found to have dislocated from the MH when the patient was reviewed 1 week later.

View Article and Find Full Text PDF

To present the successful application of fibrin glue as a surgical adjunct in the management of complex rhegmatogenous retinal detachment (RRD). In this retrospective case series, fibrin glue was used as a surgical adjunct in 5 cases of complex RRD. In each case, standard pars plana vitrectomy and laser retinopexy were performed by the same surgeon.

View Article and Find Full Text PDF

Gap injuries to the peripheral nervous system result in pain and loss of function, without any particularly effective therapeutic options. Within this context, mesenchymal stem cell (MSC)-derived exosomes have emerged as a potential therapeutic option. Thus, the focus of this study was to review currently available data on MSC-derived exosome-mounted scaffolds in peripheral nerve regeneration in order to identify the most promising scaffolds and exosome sources currently in the field of peripheral nerve regeneration.

View Article and Find Full Text PDF

Background: As a new technique developed in recent years, bronchoscopic intervention therapy has the advantages of minimal invasion, high safety and repeatability. The aim of this study is to investigate the clinical characteristics of bronchopleural fistula (BPF) induced by surgeries for lung malignancies or benign diseases and the effect of bronchoscopic intervention therapy for BPF, so as to provide support for prevention and treatment of BPF.

Methods: Data 64 patients with BPF who were treated by bronchoscopic intervention in Respiratory Disease Center of Dongzhimen Hospital, Beijing University of Chinese Medicine from June 2020 to September 2023 were collected.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!