A new IC-ESI-MS/MS method, with simple sample preparation procedure, has been developed for quantification and confirmation of perchlorate (ClO4-) anions in water, fresh and canned food, wine and beer samples at low part-per-trillion (ng l(-1)) levels. To the best of our knowledge, this is the first time an analytical method is used for determination of perchlorate in wine and beer samples. The IC-ESI-MS/MS instrumentation consisted of an ICS-2500 ion chromatography (IC) system coupled to either an API 2000 or an API 3200 mass spectrometer. The IC-ESI-MS/MS system was optimized to monitor two pairs of precursor and fragment ion transitions, i.e., multiple reaction monitoring (MRM). All samples had oxygen-18 isotope labeled perchlorate internal standard (ISTD) added prior to extraction. Chlorine isotope ratio (35Cl/37Cl) was used as a confirmation tool. The transition of 35Cl16O4- (m/z 98.9) into 35Cl16O3- (m/z 82.9) was monitored for quantifying the main analyte; the transition of 37Cl16O4- (m/z 100.9) into 37Cl16O3- (m/z 84.9) was monitored for examining a proper isotopic abundance ratio of 35Cl/37Cl; and the transition of 35Cl18O4- (m/z 107.0) into 35Cl18O3- (m/z 89.0) was monitored for quantifying the internal standard. The minimum detection limit (MDL) for this method in de-ionized water is 5 ng l(-1) (ppt) using the API 2000 mass spectrometer and 0.5 ng l(-1) using the API 3200 mass spectrometer. Over 350 food and beverage samples were analyzed mostly in triplicate. Except for four, all samples were found to contain measurable amounts of perchlorate. The levels found ranged from 5 ng l(-1) to 463.5+/-6.36 microg kg(-1) using MRM 98.9-->82.9 and 100 microl injection.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.aca.2006.03.012 | DOI Listing |
Nat Protoc
January 2025
Department Proteomics and Signal Transduction, Max Planck Institute of Biochemistry, Martinsried, Germany.
Deep and accurate proteome analysis is crucial for understanding cellular processes and disease mechanisms; however, it is challenging to implement in routine settings. In this protocol, we combine a robust chromatographic platform with a high-performance mass spectrometric setup to enable routine yet in-depth proteome coverage for a broad community. This entails tip-based sample preparation and pre-formed gradients (Evosep One) combined with a trapped ion mobility time-of-flight mass spectrometer (timsTOF, Bruker).
View Article and Find Full Text PDFJ Chromatogr B Analyt Technol Biomed Life Sci
January 2025
School of Pharmacy, Lanzhou University, Lanzhou 730030 China; Department of Pharmacy, The Second Hospital & Clinical Medical School, Lanzhou University, Lanzhou 730030 China. Electronic address:
Objective: To develop a rapid, convenient, accurate, and low-residual-effect ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method for the determination of polymyxin B sulfate and colistin sulfate in the blood of patients with multidrug-resistant bacterial infections, as well as caspofungin acetate in the blood of patients with fungal infections, thus facilitating the rational use of antibiotics in clinical applications.
Methods: All analytes were diluted with 0.2 % aqueous formic acid, and plasma proteins were precipitated using acetonitrile.
Anal Chem
January 2025
Research Unit of Environmental Toxicology, School of Public Health, China Medical University, Shenyang 110122, China.
Although cathepsin S is transported from the spleen to the liver, where it cleaves collagen XVIII to produce endostatin and plays a critical role in the onset of early liver fibrosis, the relationship between liver fibrosis and spleen function remains underexplored. Given the roles of phosphorylation in disease, understanding its regulatory mechanism in early liver fibrosis is crucial. Despite advances in mass spectrometry enhancing phosphoproteomics, its application is limited by small clinical samples and subtle protein changes.
View Article and Find Full Text PDFPLoS One
January 2025
Electrical and Computer Engineering, University of Denver, Denver, Colorado, United States of America.
Amino acid identification is crucial across various scientific disciplines, including biochemistry, pharmaceutical research, and medical diagnostics. However, traditional methods such as mass spectrometry require extensive sample preparation and are time-consuming, complex and costly. Therefore, this study presents a pioneering Machine Learning (ML) approach for automatic amino acid identification by utilizing the unique absorption profiles from an Elliptical Dichroism (ED) spectrometer.
View Article and Find Full Text PDFAm J Transl Res
December 2024
Department of Pharmacy, The Fourth Hospital of Hebei Medical University Shijiazhuang 050000, Hebei, China.
Objectives: The aim of this study was to establish an ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method for the detection of osimertinib in rat plasma, lung and brain tissues.
Methods: Forty-eight rats were randomly divided into an experimental group (receiving osimertinib at doses of 5, 8, and 10 mg/kg) and a control group. After continuous intragastric administration for 15 days, samples of blood, lung, and brain tissue were collected.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!