The role of tissue characterization by intravascular ultrasound (IVUS) imaging of the aortic wall has not been well established. The artificial neural networks (ANNs) are a promising tool for image classification. The aim of the study was to assess the texture correlation between matching IVUS and histologic images of the aortic wall. The computer-based discrimination of pathology within the data sets was also evaluated. In vitro IVUS images and histologic sections from 36 aortic segments were compared using texture parameters that produced the best correlation or the highest discriminative value. The images were classified as normal or abnormal with variable degrees of pathology. Tissue characterization was performed by a nearest neighbor classifier, linear discriminant analysis (LDA) and the ANN-based approach. Good agreement was observed between IVUS and the histologic reference with a correlation coefficient of r = 0.89, r = 0.76 and r = 0.71 for the three most successful texture parameters. The ANN-based approach was the most effective in discriminant analysis, with a correct classification rate of 87.5% for histologic images and 79.2% for IVUS data. The study shows that ANNs are a potentially effective tool for assessment of IVUS aortic images.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ultrasmedbio.2007.06.021DOI Listing

Publication Analysis

Top Keywords

aortic wall
12
tissue characterization
12
neural networks
8
intravascular ultrasound
8
ivus histologic
8
histologic images
8
texture parameters
8
discriminant analysis
8
ann-based approach
8
ivus
6

Similar Publications

Disrupted feeding and fasting cycles as well as chronic high fat diet (HFD)-induced obesity are associated with cardiovascular disease risk factors. We designed studies that determined whether two weeks of time-restricted feeding (TRF) intervention in mice fed a chronic HFD would reduce cardiovascular disease risk factors. Mice were fed a normal diet (ND; 10% fat) ad libitum or HFD (45% fat) for 18 weeks ad libitum to establish diet-induced obesity.

View Article and Find Full Text PDF

Transaortic endarterectomy (TE) is an effective and durable method of restoring patency in the aorta afflicted with atherosclerotic disease, which most commonly affects the infrarenal aorta and common iliac artery. When the suprarenal aorta is involved, the disease is usually confined to the orifices of the visceral vessels without obstruction of the aortic lumen. In rare cases, dense, calcified, exophytic, and amorphous lesions causing severe luminal obstruction, termed coral reef atherosclerosis (CRA) of the suprarenal aorta, may occur.

View Article and Find Full Text PDF

Aims: Aortic wall stiffening in ascending thoracic aortic aneurysm (aTAA) is common. However, the spatial and temporal relationships between stiffness, aortic size, and growth in aTAA remain unclear.

Methods And Results: In this single-centre retrospective study, we utilized vascular deformation mapping to extract multi-directional aortic motion, aortic distensibility, and aortic growth in a multi-planar fashion from multi-phasic ECG-gated computed tomography angiograms.

View Article and Find Full Text PDF

Purpose: Although idiopathic scoliosis is a common three-dimensional deformity, there is a lack of studies evaluating the associations between the aortic-vertebral distance (AVD) and spinal deformities in all planes. The study therefore aimed to evaluate how the coronal and sagittal curvature, vertebral rotation and aortic-vertebral angle (AVA) affect the AVD in idiopathic scoliosis.

Methods: The AVD, AVA, vertebral rotation and curve angles were measured on preoperative magnetic resonance imaging and radiographs in 46 patients who underwent posterior spinal fusion with pedicle screw instrumentation for idiopathic scoliosis Lenke types 1 and 2.

View Article and Find Full Text PDF

Analysis of the haemodynamic changes caused by surgical and transcatheter aortic valve replacements by means fluid-structure interaction simulations.

Comput Biol Med

January 2025

UCL Mechanical Engineering, University College London, UK; Ri.MED Foundation, Palermo, Italy; University of Palermo, Department of Engineering, Palermo, Italy. Electronic address:

Aortic valve replacements, both surgical and transcatheter, are nowadays widely employed treatments. Although clinically effective, these procedures are correlated with potentially severe clinical complications which can be associated with the non-physiological haemodynamics that they establish. In this work, the fluid dynamics changes produced by surgical and transcatheter aortic valve replacements are analysed and compared with an ideal healthy native valve configuration, employing advanced fluid-structure interaction (FSI) simulations.