A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 144

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 144
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 212
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3106
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

European multicenter evaluation of commercial enzyme immunoassays for detecting norovirus antigen in fecal samples. | LitMetric

A total of 2,254 fecal samples were tested in a European multicenter evaluation of commercially available norovirus antigen detection assays. Two commercial enzyme immunoassays, IDEIA Norovirus (Oxoid; Thermo Fisher Scientific, Ely, United Kingdom) and RIDASCREEN Norovirus (R-Biopharm, Darmstadt, Germany), were included in the evaluation, and their performance was compared with the results of reverse transcription-PCR (RT-PCR). Included in the evaluation were samples collected in sporadic cases of gastroenteritis, samples from outbreaks in which two or more samples were collected, well-characterized samples representing genotypes currently cocirculating within Europe, and samples collected from patients with gastroenteritis caused by a pathogen other than norovirus. The sensitivities and specificities of the IDEIA Norovirus and RIDASCREEN Norovirus assays were 58.93 and 43.81% and 93.91 and 96.37%, respectively, compared with RT-PCR. The sensitivities of both assays for outbreak investigations improved when six or more samples from an outbreak were examined. The IDEIA Norovirus assay exhibited reactivity to a broader range of norovirus genotypes than the RIDASCREEN Norovirus assay, which showed genotype-dependent sensitivities. The results indicate that, if used, these assays should serve as screening assays and the results should be confirmed by RT-PCR.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2168115PMC
http://dx.doi.org/10.1128/CVI.00214-07DOI Listing

Publication Analysis

Top Keywords

ideia norovirus
12
ridascreen norovirus
12
samples collected
12
norovirus
10
european multicenter
8
multicenter evaluation
8
commercial enzyme
8
enzyme immunoassays
8
norovirus antigen
8
samples
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!