Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
The in vivo precision (reproducibility) of quantitative MRI is of particular importance in osteoarthritis (OA) progression of small magnitude and response to therapy. In this study, three-dimensional high-resolution MRI performed at 7 T was used to assess the short-term reproducibility of measurements of mean tibial cartilage thickness in a meniscectomized guinea pig model of OA. MR image acquisition was repeated five times in nine controls (SHAM) and 10 osteoarthritic animals 3 months after meniscectomy (MNX), in vivo. The animals were then killed for histomorphometric assessment and correlation with the MRI-based measurements. Medial tibial cartilage thickness was measured on MR images using semi-automatic dedicated 3D software developed in-house. The reproducibility of measurements of cartilage thickness was assessed by five repeated MRI examinations with a short recovery delay between examinations (48 h). The computed coefficients of variation were 8.9% for the SHAM group and 8.2% for the MNX group. The coefficients of variation were compatible with expected thickness variations between normal and pathological animals. A positive agreement and significant partial correlation (Spearman r' = 0.74; P < 0.01) between the MRI and histomorphometric data was established. Three-dimensional high-resolution MRI is a promising non-invasive research tool for in vivo follow-up. This modality could be used for staging and monitoring therapy response in small-animal models of OA.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/nbm.1198 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!