Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: The economic, accurate, and rapid screening of foals for failure of transfer of passive immunity (FPT) is essential to ensure timely intervention.
Hypothesis: Infrared (IR) spectroscopy of foal sera and pattern recognition may be used to diagnose FPT and quantify serum IgG.
Samples: Sera from 194 foals (24-72 hours) with serum immunoglobulin G (IgG) concentrations determined previously by radial immunodiffusion assay (RID) were used.
Methods: IR spectra were recorded for the serum samples, and the data were randomly divided into training and independent test sets, each containing both FPT-positive (IgG <400 mg/dL) and non-FPT samples. A genetic optimal region selection algorithm and linear discriminant analysis were used to partition the training spectra, and the resulting classifier was then validated by comparing the IR-predicted FPT status for each of the test samples to that provided by the RID IgG assay. A quantitative IR-based assay for IgG was developed using partial least squares (PLS) and validated by testing its ability to predict IgG concentrations.
Results: Specificity, sensitivity, and accuracy for the combined data were 92.5, 96.8, and 95.9%, respectively. Corresponding positive (88.1%) and negative predictive (98.0%) values determined a success rate of 95-97% as compared to RID-based IgG concentrations. The IR-based quantitative assay yielded correlation coefficients for IR spectroscopy versus RID-based IgG concentrations of 0.90 and 0.86 for the training and test sets, respectively.
Conclusions And Clinical Importance: The overall performance of the IR-based test was similar to that of the colorimetric assay and was superior and more economic than other available tests.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1892/0891-6640(2007)21[828:uofisf]2.0.co;2 | DOI Listing |