A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Spatial resolution requirements for acquisition of the virtual screening slide for digital whole-specimen breast histopathology. | LitMetric

We examined the effect of lateral spatial resolution and reader specialty on the accuracy of detection of breast cancer. The motivation for this pilot study was the need to acquire and display very large data sets in whole-specimen 3D digital breast histopathology imaging. The ultimate goal is to determine the minimum resolution adequate for detection of malignancy. Twenty-three histologic slides were selected from breast pathology cases and digitized at 2 sampling distances (3.2 and 1.9 microm pixels). Images were viewed by 14 pathologists, of whom 5 had breast pathology as their primary specialty. The readers assessed the likelihood of malignancy on a 5-point Likert scale, and provided a provisional diagnosis. For the detection task, sensitivity, specificity, overall accuracy of detection, and area under the receiver-operator curve were calculated. An overall diagnostic score, and scores grouped by malignancy type, were also computed. Outcome measures were examined for significant resolution and specialty effects. Increasing the lateral resolution significantly improved accuracy in diagnosis (P=.004) but no effect was found for detection. Breast specialists achieved significantly higher scores for all outcome measures except specificity. Differences in performance between the 2 groups of readers tended to be greater for the diagnostic task compared to detection, especially at the higher resolution. However, specimen coverage may also be a significant factor. Factors related to the readers may have also affected performance in this study. Based on these results, a more comprehensive study should examine pixel sizes between 0.7 and 1.9 microm.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.humpath.2007.04.006DOI Listing

Publication Analysis

Top Keywords

spatial resolution
8
breast histopathology
8
accuracy detection
8
detection breast
8
breast pathology
8
outcome measures
8
breast
6
detection
6
resolution
5
resolution requirements
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!