Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Distinguishing Alzheimer's disease (AD) and frontotemporal dementia (FTD) currently relies on a clinical history and examination, but positron emission tomography with [(18)F] fluorodeoxyglucose (FDG-PET) shows different patterns of hypometabolism in these disorders that might aid differential diagnosis. Six dementia experts with variable FDG-PET experience made independent, forced choice, diagnostic decisions in 45 patients with pathologically confirmed AD (n = 31) or FTD (n = 14) using five separate methods: (1) review of clinical summaries, (2) a diagnostic checklist alone, (3) summary and checklist, (4) transaxial FDG-PET scans and (5) FDG-PET stereotactic surface projection (SSP) metabolic and statistical maps. In addition, we evaluated the effect of the sequential review of a clinical summary followed by SSP. Visual interpretation of SSP images was superior to clinical assessment and had the best inter-rater reliability (mean kappa = 0.78) and diagnostic accuracy (89.6%). It also had the highest specificity (97.6%) and sensitivity (86%), and positive likelihood ratio for FTD (36.5). The addition of FDG-PET to clinical summaries increased diagnostic accuracy and confidence for both AD and FTD. It was particularly helpful when raters were uncertain in their clinical diagnosis. Visual interpretation of FDG-PET after brief training is more reliable and accurate in distinguishing FTD from AD than clinical methods alone. FDG-PET adds important information that appropriately increases diagnostic confidence, even among experienced dementia specialists.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1093/brain/awm177 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!