Asymptomatic subclavian vein occlusion following insertion of a permanent pacemaker (PPM) or implantable cardioverter-defibrillator (ICD) is not uncommon. We report a case of a dual-chamber PPM in a patient with an unrecognized left subclavian vein occlusion who developed massive left arm edema following ipsilateral implantation of an arteriovenous (AV) hemodialysis graft. We recommend that patients with pre-existing PPM or ICD leads who are in need of vascular access for hemodialysis should have the AV shunts placed in the contralateral arm. If this is unavoidable, then preoperative subclavian vein screening for patency should be mandatory, even in asymptomatic patients. Sonography is an appropriate initial test in such a situation.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/jcu.20405 | DOI Listing |
JBJS Case Connect
January 2025
Department of Orthopedic Surgery, Albany Medical Center, Albany, New York.
Case: We present the case of a 24-year-old woman who sustained a left midshaft clavicle fracture with acute subclavian artery compression, subclavian vein laceration, and complete brachial plexus palsy after a motor vehicle collision. The patient underwent urgent open reduction internal fixation of the clavicle and repair of the subclavian vein. Two years later, she underwent opponensplasty and flexor digitorum profundus tendon transfers.
View Article and Find Full Text PDFSci Rep
January 2025
Medical Oncology Department, Central University Hospital of Asturias, Oviedo, Spain.
Totally implantable central venous catheters (CVCs) are widely used in the management of patients with malignant diseases. Conventionally, port implantations were carried out by general surgeons and vascular radiologists. In recent years, the medical staff of the Medical Oncology department at the Central University Hospital of Asturias (HUCA) has developed a simplified methodology for the routine implantation of these devices.
View Article and Find Full Text PDFIndian J Nephrol
July 2024
Department of Medicine, INHS Asvini, Mumbai, India.
Background: External jugular vein (EJV) is used to insert tunneled dialysis catheter (TDC) in patients with no AVF and exhausted right internal jugular veins (IJV). There is scarce data on TDC insertion in EJV by nephrologists with fluoroscopy guidance.
Materials And Methods: This was a prospective observational study that included hemodialysis patients with exhausted right IJV access who underwent EJV TDC insertion, and excluded occluded ipsilateral brachiocephalic vein or superior vena cava, EJV < 5 mm diameter, or patients with existing EJV TDC.
J Clin Med
January 2025
Federal Research and Clinical Center of Intensive Care Medicine and Rehabilitology, Moscow 107031, Russia.
Ultrasonographic assessment of the diameters of various veins and their indices are among the most applied diagnostic tools for evaluating fluid responsiveness in clinical practice. Despite their widespread use, there is no definitive answer on which is preferable. Our study aimed to investigate the diagnostic accuracy of different venous diameters and their indices to assess fluid responsiveness.
View Article and Find Full Text PDFBackground: When inserting central venous catheters, inadvertent injury of major vessels is a rare yet critical complication. Direct surgery is sometimes overly invasive. This report describes a subclavian artery injury caused by inadvertent cannulation of a dialysis catheter, successfully treated with a covered stent.