Asymptomatic subclavian vein occlusion following insertion of a permanent pacemaker (PPM) or implantable cardioverter-defibrillator (ICD) is not uncommon. We report a case of a dual-chamber PPM in a patient with an unrecognized left subclavian vein occlusion who developed massive left arm edema following ipsilateral implantation of an arteriovenous (AV) hemodialysis graft. We recommend that patients with pre-existing PPM or ICD leads who are in need of vascular access for hemodialysis should have the AV shunts placed in the contralateral arm. If this is unavoidable, then preoperative subclavian vein screening for patency should be mandatory, even in asymptomatic patients. Sonography is an appropriate initial test in such a situation.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jcu.20405DOI Listing

Publication Analysis

Top Keywords

subclavian vein
12
arm edema
8
permanent pacemaker
8
vein occlusion
8
massive arm
4
edema arteriovenous
4
arteriovenous dialysis
4
dialysis shunt
4
shunt creation
4
creation patient
4

Similar Publications

Case: We present the case of a 24-year-old woman who sustained a left midshaft clavicle fracture with acute subclavian artery compression, subclavian vein laceration, and complete brachial plexus palsy after a motor vehicle collision. The patient underwent urgent open reduction internal fixation of the clavicle and repair of the subclavian vein. Two years later, she underwent opponensplasty and flexor digitorum profundus tendon transfers.

View Article and Find Full Text PDF

Totally implantable central venous catheters (CVCs) are widely used in the management of patients with malignant diseases. Conventionally, port implantations were carried out by general surgeons and vascular radiologists. In recent years, the medical staff of the Medical Oncology department at the Central University Hospital of Asturias (HUCA) has developed a simplified methodology for the routine implantation of these devices.

View Article and Find Full Text PDF

Background: External jugular vein (EJV) is used to insert tunneled dialysis catheter (TDC) in patients with no AVF and exhausted right internal jugular veins (IJV). There is scarce data on TDC insertion in EJV by nephrologists with fluoroscopy guidance.

Materials And Methods: This was a prospective observational study that included hemodialysis patients with exhausted right IJV access who underwent EJV TDC insertion, and excluded occluded ipsilateral brachiocephalic vein or superior vena cava, EJV < 5 mm diameter, or patients with existing EJV TDC.

View Article and Find Full Text PDF

Ultrasonographic assessment of the diameters of various veins and their indices are among the most applied diagnostic tools for evaluating fluid responsiveness in clinical practice. Despite their widespread use, there is no definitive answer on which is preferable. Our study aimed to investigate the diagnostic accuracy of different venous diameters and their indices to assess fluid responsiveness.

View Article and Find Full Text PDF

Background: When inserting central venous catheters, inadvertent injury of major vessels is a rare yet critical complication. Direct surgery is sometimes overly invasive. This report describes a subclavian artery injury caused by inadvertent cannulation of a dialysis catheter, successfully treated with a covered stent.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!