A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Multicenter safety and efficacy analysis of assisted closure after antegrade arterial punctures using the StarClose device. | LitMetric

Purpose: To evaluate the safety and efficacy of the StarClose device for closure of antegrade punctures following infrainguinal endovascular interventions.

Methods: A retrospective review was conducted of 221 consecutive patients treated with the StarClose device in a 12-month period at 5 centers (4 French and 1 British). Of these, 107 patients (69 men; median age 75 years, range 44-93) were from the UK cohort (111 closures), and 94 patients (75 men; median age 67 years, range 32-95) were from the French cohort (111 closures). Technical success, complication rates, demographic data, medical history, and procedural details were gathered for all patients. Residual bleeding and the requirement for additional manual compression were recorded when the device failed. Clinical evaluation was performed at discharge; color-coded duplex ultrasonography was done in a subset of French patients.

Results: The overall technical success rate was 94.6% (210/222; 95% CI 3.1%-9.2%). The results were similar in the 2 cohorts: 95.5% (106/111; 95% CI 1.9%-10.1%) in the UK and 93.7% (104/111; 95% CI 3.1%-12.4%) in France. The 12 failures (5 UK and 7 France) were due to several mechanisms: device failure (n=5), obesity (n=1), groin scarring (n=2), and unexplained (n=4). In 2 failed cases, open surgical closure of the arteriotomy was performed because pressure hemostasis failed. Two pseudoaneurysms were observed: one after immediate failure was successfully treated by prolonged pressure; the other, after apparent success of the device, required surgical therapy. The incidence of serious vascular complication was 1.8% (4/222; 95% CI 0.7%-4.5%); 2 patients from each cohort.

Conclusion: The StarClose device safely and effectively closes antegrade punctures after infrainguinal endovascular intervention, even in patients who would be considered to be at high risk for puncture-site bleeding. However, a randomized trial would be required to support any definitive recommendations.

Download full-text PDF

Source
http://dx.doi.org/10.1177/152660280701400410DOI Listing

Publication Analysis

Top Keywords

starclose device
16
safety efficacy
8
closure antegrade
8
antegrade punctures
8
punctures infrainguinal
8
infrainguinal endovascular
8
patients men
8
men median
8
median age
8
age years
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!