A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Light intensity evaluation of laser-induced fluorescence after caries removal using an experimental caries staining agent. | LitMetric

Objective: The purpose of this study was to evaluate the intensity of fluorescent light reflected from cavity wall dentin, after dentin stained by an experimental caries detecting liquid was removed.

Background Data: The conventional caries detecting liquid tends to penetrate dentin too deeply. On the other hand, DIAGNOdent has gradually gained recognition and established itself as a caries detection device using a laser beam.

Method: An experimental caries staining liquid or the conventional caries staining liquid was applied in the same cavity to observe for differences in dye penetration. Intensity of fluorescence reflected from treated dentin was measured by DIAGNOdent.

Results: The mean DIAGNOdent value after removing the tooth substance stained by the experimental liquid was 17.9+/-4.1, compared with 7.7+/-2.7 by conventional one.

Conclusion: Light intensity evaluation of laser-induced fluorescence suggested that the experimental caries detecting liquid did not penetrate the dentin which should be preserved, hence avoiding overtreatment.

Download full-text PDF

Source
http://dx.doi.org/10.4012/dmj.26.307DOI Listing

Publication Analysis

Top Keywords

experimental caries
16
caries staining
12
caries detecting
12
detecting liquid
12
light intensity
8
intensity evaluation
8
evaluation laser-induced
8
laser-induced fluorescence
8
caries
8
stained experimental
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!