Objective: To determine the diagnostic accuracy of computed tomography colonography (CTC) compared with conventional colonoscopy (CC).
Methods: Patients with an indication of CC were included. Fifty patients underwent CTC using multidetector CT before diagnostic colonoscopy was performed by an expert colonoscopist. Diagnostic accuracy was assessed individually both for each polyp and for each patient.
Results: Fifty patients were included and 40 polyps were analyzed. The by-polyp sensitivity of CTC was 15% for polyps 5 mm or less, 75% for polyps 5- 10 mm and 75% for polyps 10 mm or larger. By-patient specificity was 6% for polyps 5 mm or less, 75% for polyps 5-10 mm and 80% for polyps 10 mm or larger. The specificity of CTC was 94%. CTC was preferred over CC by 90% of the patients. The mean colonoscopy examination time was 30 minutes for CC and 35 minutes for CTC (p < 0.05).
Conclusions: The sensitivity of CTC is moderate in detecting polyps larger than 10 mm, low in detecting 5-10 mm polyps and very low in detecting those less than 5 mm. The overall specificity of the procedure was 94%. Procedure time was lower with CC than with CTC but the latter was better tolerated by most patients.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1157/13108816 | DOI Listing |
Background And Aims: The 2020 United States Multi-Society Task Force on Colorectal Cancer guidelines for surveillance after colonoscopy with polypectomy introduced significant changes in surveillance intervals. We sought to identify rates of adherence to these new guidelines at an academic medical center.
Methods: Average-risk screening colonoscopies where 1 to 4 polyps <10 mm were removed between January 1, 2020, and June 30, 2021 were included.
Water Res
January 2025
National Engineering Laboratory for Advanced Municipal Wastewater Treatment and Reuse Technology, Engineering Research Center of Beijing, Beijing University of Technology, Beijing 100124, PR China. Electronic address:
Hydroxylamine (HA) dosing is an effective strategy for promoting partial nitrification (PN); however, its impact on endogenous denitrification remains underexplored. In this study, long-term continuous HA dosing (1.4 mg/L) was introduced for over 110 days in a pilot-scale anaerobic/aerobic/anoxic (AOA) system treating municipal wastewater (66.
View Article and Find Full Text PDFIntroduction: Controversy remains regarding transparent cap-assisted technique improves adenoma detection rate (ADR) in colonoscopy. We aimed to investigate the effect of transparent cap-assisted colonoscopy on ADR and other colonoscopy performance.
Methods: We performed sub-analysis of an international, multicenter, open-label database containing colonoscopy data from 11 centers in 4 Asian countries/regions on patients who underwent colonoscopy.
Gut Liver
January 2025
Department of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea.
Background/aims: We investigated the clinical practice patterns of Korean endoscopists for the endoscopic resection of colorectal polyps.
Methods: From September to November 2021, an online survey was conducted regarding the preferred resection methods for colorectal polyps, and responses were compared with the international guidelines.
Results: Among 246 respondents, those with <4 years, 4-9 years, and ≥10 years of experience in colonoscopy practices accounted for 25.
Front Immunol
December 2024
Department of Pathology, Affiliated Hospital of Jining Medical University, Jining, Shandong, China.
The rare gastrointestinal tract epithelial polyp known as a pyloric gland adenoma (PGA) is more common in elderly women and uncommon in the duodenum. There are reports of two PGA cases involving high-grade intraepithelial neoplasia. A 75-year-old man was admitted to the hospital as Patient 1 due to "epigastric distension and pain for more than 10 days".
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!