Background: We report successful treatment of a patient 6 years after ascending aorta and aortic valve replacement suffering from a combination of two pseudoaneurysms. The first of them originated from the coronary ostial suture line and the second pseudoaneurysm originated from the distal suture line.
Methods: We performed re-replantation of the left main trunk to the prosthesis and then we resected the pseudoaneurysm originating from the distal suture line and we replaced the entire aorta by a vascular graft.
Results: The postoperative convalescence was uneventful, the patient was discharged two weeks after the surgery. The patient is currently in a very good condition one year after the surgery.
Conclusions: Coronary ostial pseudoaneurysm in patients after ascending aorta and aortic valve replacement with the use of "button technique" is a quite rare situation. The combination of two pseudoaneurysms originating from different suture lines in one patient seems to be unique in literature reviews.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.5507/bp.2007.024 | DOI Listing |
Cureus
November 2024
Internal Medicine, Olabisi Onabanjo University, Ago-Iwoye, NGA.
Background Combining left atrial appendage closure with catheter ablation (LAACCA) has been proposed as a potential approach to improving outcomes by simultaneously addressing arrhythmia and reducing stroke risk. This study compares the in-hospital outcomes of LAACCA vs. catheter ablation (CA) alone for atrial fibrillation (AFib) in patients with heart failure with reduced ejection fraction (HFrEF).
View Article and Find Full Text PDFJ Surg Case Rep
January 2025
Department of Trauma Surgery, University of the Witwatersrand, Floor 7, Charlotte Maxeke Johannesburg Academic Hospital, 17 Jubilee Rd, Parktown, Johannesburg, South Africa.
Endovascular repair of aortic injuries secondary to blunt trauma has been widely described. However, literature on endovascular management in penetrating aortic injuries is scarce. The patient in this case report, a victim of penetrating thoracic aortic trauma, presented 5 days after injury with Brown-Sequard syndrome and a contained aortic injury (pseudoaneurysm) and was haemodynamically stable.
View Article and Find Full Text PDFAnn Chir Plast Esthet
December 2024
Plastic and Reconstructive Surgery, Department of Precision Medicine in Medical, Surgical and Critical Care - University of Palermo, Palermo, Italy.
JACC Case Rep
November 2024
Cardiovascular and Thoracic Surgery Department, Heart and Vascular Institute, West Virginia University, Morgantown, West Virginia, USA.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!