A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Quantitative perfusion imaging with pulsed arterial spin labeling: a phantom study. | LitMetric

Quantitative perfusion imaging with pulsed arterial spin labeling: a phantom study.

Magn Reson Med Sci

Department of Clinical Radiology, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan.

Published: October 2007

Purpose: Pulsed arterial spin labeling (PASL) is a magnetic resonance (MR) method for measuring cerebral blood flow. Although several validation studies for PASL in animals and humans have been reported, no reports have detailed the fundamental study of PASL using a flow phantom. We compared the true and theoretical flow rates in a flow phantom to confirm the analytical validity of quantitative perfusion imaging with Q2TIPS sequence.

Methods: We built a flow phantom consisting of a 40-mm diameter plastic syringe filled with plastic beads and small plastic tubes 4 mm in diameter. Gd-DTPA-doped 8L water solution (0.1 mM) was circulated between the syringe and a tank through a plastic tube by a constant flow pump while the flow rate was adjusted between 0 and 2.61 cm/s. Q2TIPS sequence parameters were TI(1)=50 ms and TI(2)=1400 ms. Five imaging slices of 50 subtraction images were acquired sequentially in a distal-to-proximal direction using a single-shot echo planar imaging (EPI) technique. The theoretical flow rate calculated based upon the previously reported kinetic model for Q2TIPS was compared with the true flow rate.

Results: A good linear relationship was observed between the theoretical, F', and true flow rates, F, in a flow rate range of 1.43 to 1.95 cm/s (F'=1.024*F-1.915, R(2)=0.902). The ratio of theoretical to true flow rate was 92 (+/-) 4%.

Conclusion: Flow rate was quantified with reasonable accuracy when the entire amount of labeled bolus within the phantom could be recovered. Our experiment confirmed the analytical validity of Q2TIPS and suggested that blood flow measurement may be feasible using the Q2TIPS pulse sequence and kinetic model of the PASL equation.

Download full-text PDF

Source
http://dx.doi.org/10.2463/mrms.6.91DOI Listing

Publication Analysis

Top Keywords

flow rate
20
flow
14
flow phantom
12
true flow
12
quantitative perfusion
8
perfusion imaging
8
pulsed arterial
8
arterial spin
8
spin labeling
8
blood flow
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!