The in vivo measurement of oxygen in tissues is of great interest because of oxygen's fundamental role in life. Many methods have been developed for such measurement, but all have been limited, especially with regard to repeated measurement, degree of invasiveness, and sensitivity. We describe electron spin resonance (ESR) oximetry with paramagnetic oxygen-sensing probe for in vivo measurement of oxygen in brain tissues by home-made ESR/MR dual imaging spectroscopy. Lithium 5, 9, 14, 18, 23, 27, 32, 36-octa-n-butoxy-2,3-naphthlocyanine (LiNc-BuO) radical was employed as the solid oxygen-sensing probe, and we confirmed its ability to report partial pressure of oxygen (pO(2)) in brain tissues of live animals under normal and pathological conditions for more than a month. pO(2) measurements could also be made repeatedly on the same animal and at the same location. The implantation site of LiNc-BuO in examined rats was verified by 0.5 T magnetic resonance (MR) imaging. Septic-shock rats were used to monitor tissue oxygenation during pathological state. A decline in pO(2) levels from severe hypotension during sepsis was detected, and generation of nitric oxide (NO) in brain tissues was confirmed by NO spin trapping. ESR oximetry using oxygen-sensing probe and NO spin-trapping can be used to monitor pO(2) change and NO production simultaneously and repeatedly at the same site in examined animals.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.2463/mrms.6.83 | DOI Listing |
J Exp Biol
January 2025
Department of Zoology, University of British Columbia, Vancouver, British Columbia V6T 1Z4, Canada.
Peripheral arterial chemoreceptors monitor the levels of arterial blood gases and adjust ventilation and perfusion to meet metabolic demands. These chemoreceptors are present in all vertebrates studied to date but have not been described fully in reptiles other than turtles. The goals of this study were to 1) identify functional chemosensory areas in the South American rattlesnake (Crotalus durissus) 2) determine the neurochemical content of putative chemosensory cells in these areas and 3) determine the role each area plays in ventilatory and cardiovascular control.
View Article and Find Full Text PDFACS Sens
November 2024
Department of Biomedical Engineering, Texas A&M University, College Station, Texas 77843, United States.
Chronic diseases, including diabetes, cardiovascular diseases, and microvascular complications, contribute significantly to global morbidity and mortality. Current monitoring tools such as glucometers and continuous glucose monitors only measure one analyte; multiplexing technologies offer a promising approach for monitoring multiple biomarkers, enabling the management of comorbidities and providing more comprehensive disease insights. In this work, we describe a miniaturized optical "barcode" sensor with high biocompatibility for the continuous monitoring of glucose and oxygen.
View Article and Find Full Text PDFMol Imaging Biol
June 2024
Department of Radiation and Cellular Oncology, The University of Chicago Medical Center MC1105, 5841 S. Maryland Avenue, Chicago, IL, 60637, USA.
Molecular oxygen and its thermodynamic transformation drive nearly all life processes. Quantitative measurement and imaging of oxygen in living systems is of fundamental importance for the study of life processes and their aberrations-disease- many of which are affected by hypoxia, or low levels of oxygen. Cancer is among the disease processes profoundly affected by hypoxia.
View Article and Find Full Text PDFYakugaku Zasshi
March 2024
Graduate School of Science and Technology, Gunma University.
Molecular oxygen plays essential roles in aerobic organisms as a terminal electron acceptor in the electron transport chain in mitochondria. The intracellular oxygen concentration of the entire body is strictly regulated by a balance between the supply of oxygen from blood vessels and the consumption of oxygen in mitochondria. The disruption of oxygen homeostasis in the body often results in serious pathologies such as cancer, cerebral infarction, and chronic kidney disease, and thus considerable effort has been devoted to the development of suitable techniques allowing the qualitative and quantitative detection of tissue oxygen levels.
View Article and Find Full Text PDFSensors (Basel)
January 2024
School of Biochemistry and Cell Biology, University College Cork, Pharmacy Building, College Road, T12 K8AF Cork, Ireland.
Respirometric microbial assays are gaining popularity, but their uptake is limited by the availability of optimal O sensing materials and the challenge of validating assays with complex real samples. We conducted a comparative evaluation of four different O-sensing probes based on Pt-porphyrin phosphors in respirometric bacterial assays performed on standard time-resolved fluorescence reader. The macromolecular MitoXpress, nanoparticle NanO2 and small molecule PtGlc and PtPEG probes were assessed with cells in five growth media: nutrient broth (NB), McConkey (MC), Rapid Coliform ChromoSelect (RCC), M-Lauryl lauryl sulfate (MLS), and Minerals-Modified Glutamate (MMG) media.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!