Purpose: To prospectively compare accuracy of gray-scale subharmonic imaging (SHI) with that of standard gray-scale ultrasonography (US), power Doppler US (with and without contrast material), and mammography for the diagnosis of breast cancer, with histopathologic or clinical follow-up results as the reference standard.

Materials And Methods: This HIPAA-compliant pilot study had institutional review board approval; all subjects gave written informed consent. Fourteen women (age range, 37-66 years) had 16 biopsy-proved breast lesions. In SHI, pulses are transmitted at one frequency, but only echoes at half that frequency (the subharmonic) are received. A US scanner was modified to perform gray-scale SHI (transmitting at 4.4 and receiving at 2.2 MHz). Precontrast imaging (gray-scale US and power Doppler) was followed by contrast material-enhanced power Doppler and gray-scale SHI. A reader blinded to mammographic and pathologic findings assessed diagnosis on a six-point scale. Sensitivity, specificity, accuracy, and receiver operating characteristic (ROC) curves were computed for mammography, gray-scale and power Doppler imaging (pre- and postcontrast), and SHI.

Results: Of the 16 lesions, four (25%) were malignant. Mammography had 100% sensitivity and 20% specificity. Sensitivity and specificity, respectively, were 50% and 92% for precontrast imaging and 75% and 75% for contrast-enhanced power Doppler. SHI had 75% sensitivity and 83% specificity. Specificity was higher for all US modes than for mammography (P<.04). There were no significant differences in specificity among US modes or in sensitivity (P>or=.50). Area under the ROC curve for the diagnosis of breast cancer was 0.64 for standard gray-scale US and power Doppler US, 0.67 for contrast-enhanced power Doppler US, 0.76 for mammography, and 0.78 for SHI (P>.20). Contrast enhancement was better with SHI than with power Doppler (100% vs 44% of lesions with good or excellent enhancement; P=.004).

Conclusion: SHI appears to improve the diagnosis of breast cancer relative to conventional US and mammography, albeit on the basis of results in a very limited number of subjects.

Download full-text PDF

Source
http://dx.doi.org/10.1148/radiol.2443061588DOI Listing

Publication Analysis

Top Keywords

power doppler
32
diagnosis breast
12
breast cancer
12
gray-scale power
12
breast lesions
8
shi
8
standard gray-scale
8
power
8
doppler
8
doppler contrast
8

Similar Publications

Objective: The study aimed to explore the utility of contrast-enhanced ultrasound (CEUS) as a tool for detecting minimal inflammation in rheumatoid arthritis (RA) patients in sustained remission (SR) and to correlate the findings with Disease Activity Score 28 (DAS28) status scores and various ultrasound (US) scores.

Patients And Methods: Thirty RA patients in SR (minimum 6 months), 12 with active disease, and 10 healthy controls were included. Clinical evaluations and US assessments were performed, including grayscale US (GSUS), power Doppler US (PDUS), and Global OMERACT-EULAR Synovitis Score (GLOESS).

View Article and Find Full Text PDF

Aims: ultrasound (US) diagnosis of enthesitis is burdened of low specificity, especially when it is performed in patients with psoriasis (PsO) but without clinical psoriatic arthritis (PsA), because of mechanical, dysmetabolic and age-related concurrent enthesopatic changes. We propose a novel US score to quantify the cortical-entheseal bone remodeling burden of several peripheral entheses, aiming to improve the specificity of US for PsA-related enthesitis, and to evaluate its diagnostic value in PsO patients with subsequent diagnosis of psoriatic arthritis (PsO/PsA).

Methods: clinical and US data of 119 consecutive patients with moderate/severe PsO and nonspecific musculoskeletal symptoms, were included in this retrospective study.

View Article and Find Full Text PDF

Detection of trace gases, such as radioactive carbon dioxide, clumped isotopes, and reactive radicals, is of great interest and poses significant challenges in various fields. Achieving both high selectivity and high sensitivity is essential in this context. We present a highly selective molecular spectroscopy method based on comb-locked, mid-infrared, cavity-enhanced, two-photon absorption.

View Article and Find Full Text PDF

Combination immune checkpoint inhibitors (nivolumab and ipilimumab) are currently a first-line treatment for mesothelioma; however, not all patients respond. The efficacy of treatment is influenced by the tumor microenvironment. Murine mesothelioma tumors were irritated with various radiotherapy doses.

View Article and Find Full Text PDF

The current paper describes the creation of a simultaneous trimodal neuroimaging protocol. The authors detail their methodological design for a subsequent large-scale study, demonstrate the ability to obtain the expected physiologically induced responses across cerebrovascular domains, and describe the pitfalls experienced when developing this approach. Approach: Electroencephalography (EEG), functional near-infrared spectroscopy (fNIRS), and transcranial Doppler ultrasound (TCD) were combined to provide an assessment of neuronal activity, microvascular oxygenation, and upstream artery velocity, respectively.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!