Major complications of ultrasound-guided percutaneous radiofrequency ablations for liver malignancies: single center experience.

J Gastroenterol Hepatol

Department of Internal Medicine, Division of Hepato-Gastroenterology, Tungs' Taichung MetroHarbor Hospital, Wuchi, Taichung, Taiwan.

Published: August 2008

Background And Aim: Despite radiofrequency ablation (RFA) for malignant liver nodular lesions having promising therapeutic effects, the trade-off between the risks and benefits must be acceptable. This study analyzed the major complications of ultrasound (US)-guided percutaneous RFA procedures encountered at a single center, by a single physician.

Methods: A total of 104 patients (total 183 tumors) underwent 172 US-guided percutaneous RFA sessions between May 2003 and March 2006. The definition of major complications was according to the standardized Society of Interventional Radiology grading system (classification C-E).

Results: Eighty-six patients had hepatocellular carcinoma (HCC) and 18 patients had hepatic metastatic tumors. Nine major complications occurred from 172 RFA sessions (9/172, incidence of 5.2% per session); namely, two cases of transient liver function impairment, two cases of infection (liver abscess and septicemia), two cases of tumor seeding along the ablated track, one case of colon perforation, one case of acalculous cholecystitis and, lastly, a case of hemocholecyst. We further analyzed the possible risk factors precipitating these complications, and found that only tumor size (Pearson's correlation coefficient, 0.324; P < 0.05) and baseline liver function reserve (compensated 0%, 0/148 vs decompensated 8.3%, 2/24; P = 0.019) were significant factors for the complication of transient liver function impairment.

Conclusion: Radiofrequency ablation for liver malignancy is a safe procedure with acceptable incidence of complications. Decompensated baseline liver function reserve and large tumor size are precipitating factors for transient liver function impairment after RFA and warrant a close follow up.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1440-1746.2007.05078.xDOI Listing

Publication Analysis

Top Keywords

liver function
20
major complications
16
transient liver
12
liver
9
single center
8
radiofrequency ablation
8
us-guided percutaneous
8
percutaneous rfa
8
rfa sessions
8
function impairment
8

Similar Publications

Pifithrin-μ sensitizes mTOR-activated liver cancer to sorafenib treatment.

Cell Death Dis

January 2025

Department of Organ Transplantation and Hepatobiliary Surgery, Key Laboratory of Organ Transplantation of Liaoning Province, The First Hospital of China Medical University, Shenyang, China.

TSC2, a suppressor of mTOR, is inactivated in up to 20% of HBV-associated liver cancer. This subtype of liver cancer is associated with aggressive behavior and early recurrence after hepatectomy. Being the first targeted regimen for advanced liver cancer, sorafenib has limited efficacy in HBV-positive patients.

View Article and Find Full Text PDF

To analyze the occurrence of metabolic dysfunction-associated fatty liver disease (MAFLD) and related inflammatory indicators in obstructive sleep apnea hypopnea syndrome (OSAHS) and explore the risk factors of MAFLD. A cross-sectional study. From January 2022 to October 2024,172 patients with sleep disorders were enrolled in the First Affiliated Hospital of Soochow University,including 38 patients with non-OSAHS,53 patients with mild OSAHS,37 patients with moderate OSAHS,and 44 patients with severe OSAHS.

View Article and Find Full Text PDF

Gold nanorod in silver tetrahedron: Cysteamine mediated synthesis of SERS probes with embedded internal markers for AFP detection.

Anal Chim Acta

February 2025

The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi'an Jiaotong University, No. 28 Xianning West Road, Xi'an, 710049, China. Electronic address:

Background: Plasmonic core-shell nanostructures with embedded internal markers used as Raman probes have attracted great attention in surface-enhanced Raman scattering (SERS) immunoassay for cancer biomarkers due to their excellent uniform enhancement. However, current core-shell nanostructures typically exhibit a spherical shape and are coated with a gold shell, resulting in constrained local field enhancement.

Results: In this work, we prepared a core-shell AuNR@BDT@Ag structure by depositing silver on the surface of Raman reporter-modified gold nanorods (AuNR).

View Article and Find Full Text PDF

Purpose: This research aimed to develop and assess a Lipiodol Pickering emulsion containing anti-Programmed cell Death Ligand 1 (PD-L1) antibodies through in vitro experiments.

Materials And Methods: The emulsion was created by combining Lipiodol with poly (lactic-co-glycolic acid) (PLGA) nanoparticles and anti-PD-L1 antibodies. Confocal laser microscopy was used to evaluate the encapsulation of the antibodies within the Pickering emulsion.

View Article and Find Full Text PDF

Background & Aims: The triglyceride-glucose index (TyG) and triglyceride-glucose body mass index (TyG-BMI) have been identified as potential predictive factors for metabolic dysfunction-associated steatotic liver disease (MASLD). However, they do not include high density lipoprotein (HDL-C), which is closely related to lipid metabolism. Furthermore, there is a lack of comprehensive and longitudinal data to determine the cut-off points for different degrees of hepatic steatosis and liver fibrosis in MASLD.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!