A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Haptide-coated collagen sponge as a bioactive matrix for tissue regeneration. | LitMetric

AI Article Synopsis

  • A new type of biomaterial called Haptide-coated Collagen was developed, using a specific peptide from fibrinogen that enhances cell adhesion.
  • The optimal concentration of Haptide for enhancing cell attachment was found to be 5-10 mg Haptide/g collagen, leading to a more stable material that degrades slower than untreated collagen.
  • In animal studies, Haptized collagen attracted more fibroblasts and demonstrated improved integration with tissue, suggesting promising uses in medical fields like tissue regeneration and wound healing.

Article Abstract

We previously described a new class of conserved, cell adhesive (haptotactic) peptides, termed Haptides, based on sequences first identified in fibrinogen. Here, we describe a new biomaterial, Haptide-coated Collagen, in which the carbodiimide reagent, EDC, was used to covalently couple a Haptide (preC gamma), equivalent to the carboxy terminus of the fibrinogen gamma chain, to a cross-linked sponge composed of bovine collagen type I. The dose response of Haptide bound to collagen on cell attachment response reached a plateau at a concentration of 5-10 mg Haptide/g collagen. The Haptized-collagen was more stable to 1N NaOH, with a degradation half-time (T(1/2)) of 1.7 h, compared to 0.9 h for untreated control. Haptized collagen discs could be loaded with approximately 30% more human dermal fibroblasts or bovine aortic endothelial cells than unmodified collagen discs (p < 0.001). After a proliferation phase, Haptized collagen discs contained approximately 45% more fibroblasts than non-Haptized discs (p < 0.01). Histological analysis following sub-dermal implantation in rats indicated that at day 8, Haptized collagen sponge was less degraded than unmodified collagen sponge, attracted more endogenous fibroblasts with newly deposited collagen, and provoked less inflammatory or other adverse reactions. These results suggest potential clinical applications for Haptized collagen sponge for tissue regeneration, soft tissue augmentation, skin repair, and wound healing.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jbm.b.30905DOI Listing

Publication Analysis

Top Keywords

collagen sponge
16
haptized collagen
16
collagen discs
12
collagen
11
haptide-coated collagen
8
tissue regeneration
8
unmodified collagen
8
sponge
5
sponge bioactive
4
bioactive matrix
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!