The reproducibility of three-dimensional hydrogel surfaces based on polyurethane, poly(vinyl alcohol), and polyacrylamide (HydroGel) with respect to scanning mode (confocal vs nonconfocal), alignment (circular vs irregular), and influence of fluorescent background was investigated. It is demonstrated that, if even probe spots are provided, fluorescence intensities measured at the same photomultiplier tube gain are similar for confocal and nonconfocal scanning modes. Uneven probe spots, however, cause reduced fluorescence with confocal scanners, greater spot-to-spot variation, and higher degrees of intra- and interexperimental variability (%CV among three experiments). By using irregular instead of circular spot alignment, reproducibility (%CV) is improved for good- and bad-quality spots, in the latter case by up to three times as much. In addition, circularity can be used together with the mean-median correlation of pixel intensities as a quality measure.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.ab.2007.06.036 | DOI Listing |
Lasers Med Sci
January 2025
Department of Stomatology, the First Medical Centre, Chinese PLA General Hospital, Beijing, 100853, China.
Objective: This study evaluated dentin morphology and pulp cavity temperature changes during nanosecond‑ and microsecond‑pulse Er, Cr: YSGG laser debonding restoration and residual adhesive.
Materials And Methods: Ten caries-free teeth had their enamel removed perpendicular to the long axis, followed by bonding of glass ceramic restorations. The samples were randomly divided into two groups and subjected to Er, Cr: YSGG laser (3 mJ, 100 Hz, 100 ns), (3 mJ, 100 Hz, 150 µs) for debonding of restoration and residual adhesive on dentin surfaces.
Eur Radiol
January 2025
Shanghai Key Laboratory of Magnetic Resonance, School of Physics and Electronic Science, East China Normal University, Shanghai, China.
Objectives: To evaluate the image quality and lung nodule detectability of ultralow-dose CT (ULDCT) with adaptive statistical iterative reconstruction-V (ASiR-V) post-processed using a deep learning image reconstruction (DLIR)-based image domain compared to low-dose CT (LDCT) and ULDCT without DLIR.
Materials And Methods: A total of 210 patients undergoing lung cancer screening underwent LDCT (mean ± SD, 0.81 ± 0.
Radiol Imaging Cancer
January 2025
Department of Radiology, University Medical Center Groningen, Groningen, the Netherlands.
Purpose To validate a deep learning (DL) model for predicting the risk of prostate cancer (PCa) progression based on MRI and clinical parameters and compare it with established models. Materials and Methods This retrospective study included 1607 MRI scans of 1143 male patients (median age, 64 years; IQR, 59-68 years) undergoing MRI for suspicion of clinically significant PCa (csPCa) (International Society of Urological Pathology grade > 1) between January 2012 and May 2022 who were negative for csPCa at baseline MRI. A DL model was developed using baseline MRI and clinical parameters (age, prostate-specific antigen [PSA] level, PSA density, and prostate volume) to predict the time to PCa progression (defined as csPCa diagnosis at follow-up).
View Article and Find Full Text PDFNanomaterials (Basel)
January 2025
Département de Génie Électrique, École de Technologie Supérieure, 1100 Notre-Dame Street West, Montreal, QC H3C 1K3, Canada.
This study explored the influence of graphene oxide (GO) on morphological and mechanical properties of Nafion 115 membranes with the objective of enhancing the mechanical properties of the most widely employed membrane in Proton Exchange Membrane Water Electrolyzers (PEMWE) applications. The membrane surface was modified by ultrasonically spraying a GO solution and different annealing temperatures were tested. Scanning Electron Microscopy (SEM) cross-sectional images revealed that annealing the composite membranes was sufficient to favor an interaction between the graphene oxide and the surface of the Nafion membranes.
View Article and Find Full Text PDFPurpose: Tibial rotational deformity is a known risk factor for patellofemoral joint (PFJ) disorders. However, it is commonly associated with other abnormalities which affect the PFJ. The purpose of this study was to describe the prevalence of associated factors known to affect PFJ in patients undergoing rotational tibial osteotomy and their implication for the correction level.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!