Investigating neutron polarizabilities through Compton scattering on 3He.

Phys Rev Lett

Department of Physics and Astronomy, Ohio University, Athens, Ohio 45701, USA.

Published: June 2007

We examine manifestations of neutron electromagnetic polarizabilities in coherent Compton scattering from the helium-3 nucleus. We calculate gamma3He elastic scattering observables using chiral perturbation theory to next-to-leading order [O(e2Q)]. We find that the unpolarized differential cross section can be used to measure neutron electric and magnetic polarizabilities, while two double-polarization observables are sensitive to different linear combinations of the four neutron spin polarizabilities.

Download full-text PDF

Source
http://dx.doi.org/10.1103/PhysRevLett.98.232303DOI Listing

Publication Analysis

Top Keywords

compton scattering
8
investigating neutron
4
polarizabilities
4
neutron polarizabilities
4
polarizabilities compton
4
scattering 3he
4
3he examine
4
examine manifestations
4
manifestations neutron
4
neutron electromagnetic
4

Similar Publications

The development and calibration of a measurement system designed for assessing the performance of the avalanche photodiodes (APDs) used in the Compton scattering polarimeter of the CUSP project is discussed in this work. The designed system is able to characterize the APD gain GAPD and energy resolution across a wide range of temperatures (from -20 °C to +60 °C) and bias voltages Vbias (from 260 V to 410 V). The primary goal was to experimentally determine the GAPD dependence on the and Vbias in order to establish a strategy for stabilizing GAPD by compensating for fluctuations, acting on Vbias.

View Article and Find Full Text PDF
Article Synopsis
  • PET imaging using Zr is gaining traction for visualizing immune and cancer cells, but has limitations due to low image quality from gamma ray emissions.
  • A new prototype has been developed to improve Compton imaging within PET by redesigning the scatter detector and optimizing image reconstruction methods.
  • The upgraded WGI system showed enhanced imaging performance, including improved angular resolution, sensitivity, and reduced noise, demonstrating successful in-vivo imaging of a mouse with tumor burden after Zr labeled antibody injection.
View Article and Find Full Text PDF

Development of anticoincidence detector specializing in small-angle Compton scattering gamma rays for boron neutron capture therapy.

Appl Radiat Isot

December 2024

Division of Quantum and Radiation Engineering, Graduate School of Engineering, Osaka Metropolitan University, 1-2 Gakuen-cho, Naka-ku, Sakai, Osaka, 599-8570, Japan.

A novel anticoincidence detector is proposed for the measurement of 478 keV gamma radiation for evaluation of boron neutron capture therapy. The Compton continuum around the target photopeak position is effectively suppressed by measuring only the Compton gamma rays scattered at small angles from the primary detector. A numerical evaluation using Monte Carlo simulations estimated an 80% reduction in counts, and the developed prototype detector showed 4% suppression of the Compton continuum of cobalt-60 gamma rays.

View Article and Find Full Text PDF

Model-based CBCT scatter correction with dual-layer flat-panel detector.

Med Phys

December 2024

Research Center for Advanced Detection Materials and Medical Imaging Devices, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong, China.

Background: Recently, the popularity of dual-layer flat-panel detector (DL-FPD) based dual-energy cone-beam CT (CBCT) imaging has been increasing. However, the image quality of dual-energy CBCT remains constrained by the Compton scattered x-ray photons.

Purpose: The objective of this study is to develop a novel scatter correction method, named e-Grid, for DL-FPD based CBCT imaging.

View Article and Find Full Text PDF
Article Synopsis
  • Measuring deeply virtual Compton scattering (DVCS) on the neutron is essential for understanding the nucleon's structure through generalized parton distributions (GPDs).
  • Neutron targets help complement data obtained from polarized protons, particularly in determining the poorly understood GPD E, which is crucial for analyzing quark contributions to nucleon spin.
  • The experiment utilized a longitudinally polarized electron beam at Jefferson Lab and the CLAS12 detector to measure DVCS on the neutron for the first time, providing new insights into quark-flavor separation of relevant Compton form factors.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!