A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A phantom for effective dose measurement: organ dose distribution assessment based on a numerical approach. | LitMetric

ICRP 60 has defined the personal dose equivalent Hp(10) as an estimator of the effective dose E. Personal dosimeters, worn on the trunk, allow the measurement of the quantity Hp(10). However, the characteristics of the instrumentation and the definition of Hp(10) itself can generate differences between the two quantities, depending on the energies and on the directional distribution of the incident radiation. The objective of this study is to evaluate the possibility of the measurement of the effective dose E using an instrumented anthropomorphic phantom at workplaces. In the first step of this study, calculations of the effective dose for standard configurations are made using the Monte Carlo code MCNPX. This paper presents the model of the numerical anthropomorphic phantom and the results for whole body irradiations by broad unidirectional or plane-parallel photon beams. The results agree with those calculated by Zankl et al., so confirming the good suitability of the code and the phantom used. Then, the dose distributions inside some organs are presented and the locations of future detectors for the instrumented phantom are discussed.

Download full-text PDF

Source
http://dx.doi.org/10.1093/rpd/ncm186DOI Listing

Publication Analysis

Top Keywords

effective dose
16
anthropomorphic phantom
8
dose
7
phantom
5
phantom effective
4
dose measurement
4
measurement organ
4
organ dose
4
dose distribution
4
distribution assessment
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!