Purpose: To assess the effects of short- and long-term changes in auditory feedback on vowel and sibilant contrasts and to evaluate hypotheses arising from a model of speech motor planning.

Method: The perception and production of vowel and sibilant contrasts were measured in 8 postlingually deafened adults prior to activation of their cochlear implant speech processors, 1 month postactivation, and 1 year postactivation. Measures were taken postactivation both with and without auditory feedback. Contrast measures were also made for a group of speakers with reportedly normal hearing speaking with masked and unmasked auditory feedback.

Results: Vowel and sibilant contrasts, measured in the absence of auditory feedback after 1 month of prosthesis use, were diminished compared with their values measured before prosthesis. Contrasts measured in the absence of auditory feedback after 1 year's experience with the prosthesis were increased compared with their values after 1 month's experience. In both time samples, contrasts were enhanced when auditory feedback was restored.

Conclusion: The provision of prosthetic hearing to postlingually deafened adults impaired their phonemic contrasts at first, as their auditory feedback had novel characteristics. Once auditory feedback became recalibrated with prosthesis use, it could, in turn, revise feedforward commands that control the contrasts in its absence.

Download full-text PDF

Source
http://dx.doi.org/10.1044/1092-4388(2007/065)DOI Listing

Publication Analysis

Top Keywords

auditory feedback
32
vowel sibilant
16
sibilant contrasts
16
contrasts measured
12
auditory
9
effects short-
8
short- long-term
8
long-term changes
8
changes auditory
8
feedback
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!