A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The minute ventilation/carbon dioxide production slope is prognostically superior to the oxygen uptake efficiency slope. | LitMetric

Background: Ventilatory efficiency, commonly assessed by the minute ventilation (VE)-carbon dioxide production (VCO2) slope, has proven to be a strong prognostic marker in the heart failure (HF) population. Recently, the oxygen uptake efficiency slope (OUES) has demonstrated prognostic value, but additional comparisons to established cardiopulmonary exercise test (CPET) variables are required.

Methods And Results: A total of 341 subjects were diagnosed with HF participated in this analysis. The VE/VCO2 slope and the OUES were calculated using 50% (VE/VCO2 slope(50) or OUES(50)) and 100% (VE/VCO2 slope(100) or OUES(100)) of the exercise data. Peak oxygen consumption (VO2) was also determined. There were 47 major cardiac-related events during the 3-year tracking period. Receiver operating characteristic (ROC) curve analysis demonstrated the classification schemes for both VE/VCO2 slope and OUES calculations as well as peak VO2 were statistically significant (all areas under the ROC curve: > or = 0.74, P < .001). Area under the ROC curve for the VE/VCO2 slope(100) was, however, significantly greater than OUES(50), OUES(100), and peak VO2 (P < .05).

Conclusions: Although the OUES was a significant predictor of mortality, the VE/VCO2 slope maintained optimal prognostic value. An elevated VE/VCO2 slope may be the single best indicator of increased risk for adverse events.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.cardfail.2007.03.004DOI Listing

Publication Analysis

Top Keywords

ve/vco2 slope
16
slope oues
12
roc curve
12
dioxide production
8
slope
8
oxygen uptake
8
uptake efficiency
8
efficiency slope
8
ve/vco2 slope100
8
peak vo2
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!