Pharmaceutical and diagnostic substances like antibiotics, cytostatics and iodised X-ray contrast media (XRC) are well-known for not being metabolised and are excreted soon after application. As a result, these preparations are difficult to biodegrade and their adsorption behaviour is rather poor. Finally, the refractory properties of these substances are leading to an accumulation in the natural waterbody depending on the hydrological situation. The elimination of contrast media from urine and diluted urine solutions by ozonation was investigated using a bubble column reactor to remove and recover the formed elemental iodine from the solution by gas stripping and down stream absorption. The experiments showed that the destruction of XRCs from concentrated solutions like urine is feasible and a recycling of elemental iodine from the exhaust gas is technically and economically possible.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.2166/wst.2007.426 | DOI Listing |
JCO Clin Cancer Inform
January 2025
SimBioSys Inc, Chicago, IL.
Purpose: Perfusion modeling presents significant opportunities for imaging biomarker development in breast cancer but has historically been held back by the need for data beyond the clinical standard of care (SoC) and uncertainty in the interpretability of results. We aimed to design a perfusion model applicable to breast cancer SoC dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) series with results stable to low temporal resolution imaging, comparable with published results using full-resolution DCE-MRI, and correlative with orthogonal imaging modalities indicative of biophysical markers.
Methods: Subsampled high-temporal-resolution DCE-MRI series were run through our perfusion model and resulting fits were compared for consistency.
Radiology
January 2025
From the Department of Radiology, Shenzhen Nanshan People's Hospital, Shenzhen University, Taoyuan Rd No. 89, Nanshan District, Shenzhen 518000, Guangdong, China (H.H., Z.D., Y.Q.); Medical AI Laboratory and Guangdong Key Laboratory of Biomedical Measurements and Ultrasound Imaging, School of Biomedical Engineering, Shenzhen University Medical School, Shenzhen University, Shenzhen, China (J.M., R.L., B.H.); Department of Medical Imaging, People's Hospital of Longhua, Shenzhen, Guangdong, China (X.P., Y.Z.); and Department of Radiology, Shenzhen People's Hospital, Shenzhen, Guangdong, China (D.Z., G.H.).
Background Multiparametric MRI, including contrast-enhanced sequences, is recommended for evaluating suspected prostate cancer, but concerns have been raised regarding potential contrast agent accumulation and toxicity. Purpose To evaluate the feasibility of generating simulated contrast-enhanced MRI from noncontrast MRI sequences using deep learning and to explore their potential value for assessing clinically significant prostate cancer using Prostate Imaging Reporting and Data System (PI-RADS) version 2.1.
View Article and Find Full Text PDFSci Rep
January 2025
Department of Radiation Oncology, Henry Ford Hospital, Detroit, USA.
Best current practice in the analysis of dynamic contrast enhanced (DCE)-MRI is to employ a voxel-by-voxel model selection from a hierarchy of nested models. This nested model selection (NMS) assumes that the observed time-trace of contrast-agent (CA) concentration within a voxel, corresponds to a singular physiologically nested model. However, admixtures of different models may exist within a voxel's CA time-trace.
View Article and Find Full Text PDFBMJ Sex Reprod Health
January 2025
Obstetrics and Gynaecology, University of Edinburgh, Edinburgh, UK.
Background: Recent media attention has been given to an apparent shift away from hormonal methods of contraception. While an increase in fertility awareness-based or 'natural' family planning methods is reported in the grey literature, there are no robust data to determine any such trend in the UK.
Methods: We compared self-reported contraceptive use at conception among patients presenting for abortion at British Pregnancy Advisory Service from January to June 2018 (N=33 495) and January to June 2023 (N=55 055) using chi-square (χ) tests of association.
Insights Imaging
January 2025
Department of Radiology, Charité - Universitätsmedizin Berlin, Freie Universität Berlin and Humboldt- Universität zu Berlin, Charitéplatz 1, Berlin, Germany.
Objectives: To survey physicians' views on the risks and benefits of computed tomography (CT) in the management of septic patients and indications for and contraindications to contrast media use in searching for septic foci.
Methods: A web-based questionnaire was administered to physicians at a large European university medical center in January 2022. A total of 371 questionnaires met the inclusion criteria and were analyzed with physicians' work experience, workplace, and medical specialty as independent variables.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!