This study compares the implantation characteristics and the hemodynamic performance of the new Carpentier-Edwards Perimount Magna (CEPM) xenograft with those of the standard Perimount (CEPS) valve in the aortic position. Eighty consecutive patients surviving an aortic valve replacement with either the CEPS valve (n=40) or the CEPM prosthesis (n=40) in the supra-annular position were retrospectively reviewed. One year follow-up was complete and hemodynamic performance assessed by Doppler echocardiography. The mean valve size implanted was 21.3+/-1.7 mm (CEPS) vs. 22.2+/-1.8 mm (CEPM). The average mean pressure gradient was 13.6+/-5.1 mmHg in the CEPS group and 9.6+/-3.3 mmHg in the CEPM group (P<0.0001). Mean and peak gradients were slightly lower and the effective orifice areas (EOA) were larger for the Magna prosthesis than for the comparable standard valves: 19 mm (1.58+/-0.2 vs. 1.28+/-0.1 cm(2)), 21 mm (1.90+/-0.4 vs. 1.69+/-0.4 cm(2)), 23 mm (2.07+/-0.3 vs. 1.86+/-0.3 cm(2)), 25 mm (2.30+/-0.1 vs. 1.89+/-0.5 cm(2)). The average indexed EOA was statistically different between groups (CEPS 0.98+/-0.21 cm(2)/m(2) vs. CEPM 1.20+/-0.25 cm(2)/m(2)). Patient-prosthesis mismatch (indexed EOA

Download full-text PDF

Source
http://dx.doi.org/10.1510/icvts.2005.120352DOI Listing

Publication Analysis

Top Keywords

hemodynamic performance
12
carpentier-edwards perimount
8
perimount magna
8
ceps valve
8
magna aortic
4
aortic xenograft
4
xenograft design
4
design improved
4
improved hemodynamic
4
performance study
4

Similar Publications

Accurate rupture risk assessment is essential for optimizing treatment decisions in patients with cerebral aneurysms. While computational fluid dynamics (CFD) has provided critical insights into aneurysmal hemodynamics, most analyses focus on blood flow patterns, neglecting the biomechanical properties of the aneurysm wall. To address this limitation, we applied Fluid-Structure Interaction (FSI) analysis, an integrative approach that simulates the dynamic interplay between hemodynamics and wall mechanics, offering a more comprehensive risk assessment.

View Article and Find Full Text PDF

Introduction: Angiotensin II may reduce muscle ischemia during intermittent hemodialysis and thereby decrease the incidence and/or intensity of intradialytic muscle cramps. We aimed to test whether angiotensin II infusion during intermittent hemodialysis is safe, feasible, and effective in the attenuation of muscle cramps.

Methods: We performed a pilot, single-blinded, randomized crossover trial of patients receiving intermittent hemodialysis who frequently experience intradialytic muscle cramps.

View Article and Find Full Text PDF

This study aimed to identify the clinical characteristics of patients with burning mouth syndrome (BMS) according to the low frequency/high frequency (LF/HF) ratio in the heart rate variability test and to evaluate the potential of the LF/HF ratio as an indicator for the diagnostic or predictive assessment of patients with BMS. A total of 469 patients with BMS who visited the Oral Diseases Clinic of Kyung Hee University Korean Medicine Hospital between January 1, 2018, and December 31, 2022, were included in the study. The patients were asked to rate their tongue pain on a visual analog scale before and after treatment.

View Article and Find Full Text PDF

Analysis of the haemodynamic changes caused by surgical and transcatheter aortic valve replacements by means fluid-structure interaction simulations.

Comput Biol Med

January 2025

UCL Mechanical Engineering, University College London, UK; Ri.MED Foundation, Palermo, Italy; University of Palermo, Department of Engineering, Palermo, Italy. Electronic address:

Aortic valve replacements, both surgical and transcatheter, are nowadays widely employed treatments. Although clinically effective, these procedures are correlated with potentially severe clinical complications which can be associated with the non-physiological haemodynamics that they establish. In this work, the fluid dynamics changes produced by surgical and transcatheter aortic valve replacements are analysed and compared with an ideal healthy native valve configuration, employing advanced fluid-structure interaction (FSI) simulations.

View Article and Find Full Text PDF

Blood Flow Restricted Resistance Exercise in Well-Trained Men: Salivary Biomarker Responses and Oxygen Saturation Kinetics.

J Strength Cond Res

December 2024

Jayhawk Athletic Performance Laboratory, Wu Tsai Human Performance Alliance, University of Kansas, Lawrence, Kansas.

Eserhaut, DA, DeLeo, JM, and Fry, AC. Blood flow restricted resistance exercise in well-trained men: Salivary biomarker responses and oxygen saturation kinetics. J Strength Cond Res 38(12): e716-e726, 2024-Resistance exercise with continuous lower-limb blood flow restriction (BFR) may provide supplementary benefit to highly resistance-trained men.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!