A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Should the tricuspid valve be replaced with a mechanical or biological valve? | LitMetric

Should the tricuspid valve be replaced with a mechanical or biological valve?

Interact Cardiovasc Thorac Surg

Department of Cardiothoracic Surgery, James Cook University Hospital, Middlesbrough, UK.

Published: August 2007

A best evidence topic in cardiac surgery was written according to a structured protocol. The question addressed was whether patients requiring tricuspid replacement should have a mechanical or a biological valve. Using the reported search, 561 papers were identified. Thirteen papers represented the best evidence on the subject. The author, journal, date and country of publication, patient group studied, study type, relevant outcomes, weaknesses, results and study comments were tabulated. We conclude that there are no major differences between the insertion of a mechanical or biological tricuspid valve. Aggregating the available data it is found that the reoperation rate is similar with bioprosthetic degeneration rate being equivalent to the mechanical thrombosis rate. Conversely up to 95% of patients with a bioprosthesis still receive anticoagulation. Survival in over 1000 prostheses pooled by meta-analysis was equivalent between biological and mechanical valves.

Download full-text PDF

Source
http://dx.doi.org/10.1510/icvts.2007.159277DOI Listing

Publication Analysis

Top Keywords

mechanical biological
12
tricuspid valve
8
best evidence
8
mechanical
5
valve replaced
4
replaced mechanical
4
biological
4
biological valve?
4
valve? best
4
evidence topic
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!