Helical tomotherapy (HT) can be used for the delivery of cranio-spinal axis irradiation (CSAI) without the need for beam matching of conventional linac-based external beam irradiation. The aim of this study is to retrospectively evaluate HT plans used for treatment in nine patients treated with CSAI. Helical tomotherapy cranio-spinal axis irradiation (HT-CSAI) plans were created for each patient. Average length along the cranio-spinal axis of the PTV was 65.6 cm with a range between 53 and 74 cm. Treatment planning optimization and plan evaluation parameters were obtained from the HT planning station for each of the nine patients. PTV coverage by the 95% isodose surface ranged between 98.0 to 100.0% for all nine patients. The clinically acceptable dose variation within the PTV or tolerance range was between 0.7 and 2.5% for all nine patients. Doses to the organs at risk were clinically acceptable. An increasing length along the longitudinal axis of the PTV did not consistently increase the beam-on time indicating that using a larger jaw width had a greater impact on treatment time. With a larger jaw width it is possible to substantially reduce the normalized beam-on treatment time without compromising plan quality and sparing of organs at risk. By using a larger jaw width or lower modulation factor or both, normalized beam-on times were decreased by up to 61% as compared to the other evaluated treatment plans. From the nine cases reported in this study the minimum beam-on time was achieved with a jaw width of 5.0 cm, pitch of 0.287 and a modulation factor of 2.0. Large and long cylindrical volumes can be effectively treated with helical tomotherapy with both clinically acceptable dose distribution and beam-on time.

Download full-text PDF

Source
http://dx.doi.org/10.1177/153303460700600413DOI Listing

Publication Analysis

Top Keywords

cranio-spinal axis
16
jaw width
16
axis irradiation
12
helical tomotherapy
12
clinically acceptable
12
beam-on time
12
larger jaw
12
axis ptv
8
acceptable dose
8
organs risk
8

Similar Publications

Purpose: To investigate the current practice patterns in image-guided particle therapy (IGPT) for cranio-spinal irradiation (CSI).

Methods: A multi-institutional survey was distributed to European particle therapy centres to analyse all aspects of IGPT. Based on the survey results, a Delphi consensus analysis was developed to define minimum requirements and optimal workflow for clinical practice.

View Article and Find Full Text PDF

Many patients being investigated for Guillain-Barré syndrome (GBS) undergo unnecessary neuroimaging. The objective of this study was to determine the proportion of patients with GBS undergoing neuroimaging investigation, and to investigate any association with different GBS variants using the Brighton criteria. This cross-sectional observational study was conducted in the leading tertiary care hospital in Pakistan; 148 patients being investigated for, and subsequently diagnosed with GBS between January 2017 and March 2020 were enrolled.

View Article and Find Full Text PDF

Tomotherapy is a method of delivering rotational IMRT offering various advantages, notably for complex and large targets such as the cranio-spinal axis. This systematic literature review reports on main clinical outcomes and toxicities in patients with various cancer types that received whole craniospinal axis irradiation (CSI) using Tomotherapy and offers a comprehensive comparison between Tomotherapy and other radiotherapy delivery techniques. Databases including PubMed, PubMed Central, Embase, and Cochrane were searched using the keywords "tomotherapy" AND "craniospinal".

View Article and Find Full Text PDF

Cranio-spinal irradiation (CSI) treatment of embryonal tumors is associated with long-term endocrine and neuro-cognitive sequelae. As an example, the radiation regiment for standard risk medulloblastoma is 23.4 Grays (Gy) CSI followed by a boost of 30.

View Article and Find Full Text PDF

Treatment planning for intensity modulated proton therapy (IMPT) can be significantly improved by reducing the time for plan calculation, facilitating efficient sampling of the large solution space characteristic of IMPT treatments. Additionally, fast plan generation is a key for online adaptive treatments, where the adapted plan needs to be ideally available in a few seconds. However, plan generation is a computationally demanding task and, although dose restoration methods for adaptive therapy have been proposed, computation times remain problematic.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!