When human tooth enamel is observed with the Transmission Electron Microscope (TEM), a structural defect is registered in the central region of their nanometric grains or crystallites. This defect has been named as Central Dark Line (CDL) and its structure and function in the enamel structure have been unknown yet. In this work we present the TEM analysis to these crystallites using the High Angle Annular Dark Field (HAADF) technique. Our results suggest that the CDL region is the calcium richest part of the human tooth enamel crystallites.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10856-007-3174-7DOI Listing

Publication Analysis

Top Keywords

human tooth
12
tooth enamel
12
central dark
8
enamel crystallites
8
stem-haadf electron
4
electron microscopy
4
microscopy analysis
4
analysis central
4
dark defect
4
defect human
4

Similar Publications

This study aimed to evaluate the histological success of pulpotomy in primary molars using white mineral trioxide aggregate (WMTA) mixed with 2.25% sodium hypochlorite (NaOCl) gel and to evaluate in vitro its physical and chemical properties. The study had a clinical stage and an in-vitro stage.

View Article and Find Full Text PDF

Mesenchymal stem cells (MSCs) have been widely used in the treatment of various inflammatory diseases. The inadequate understanding of MSCs and their heterogeneity can impact the immune environment, which may be the cause of the good outcomes of MSCs-based therapy that cannot always be achieved. Recently, stem cells from human exfoliated deciduous teeth (SHED) showed great potential in inflammatory and autoimmune diseases due to their immature properties compared with MSCs.

View Article and Find Full Text PDF

This micro-computed tomography (micro-CT) analysis in vitro study was designed to compare void volume in root canal fillings performed using the single-cone (SC) technique and the continuous wave condensation (CWC) technique with bioceramic (BC) sealer. Forty human-extracted, single-rooted mandibular premolars were cleaned, shaped, and divided into two groups (n = 20) based on the obturation technique. In the first group, obturation was performed using the CWC technique with TotalFill HiFlow BC sealer.

View Article and Find Full Text PDF

Introduction: Guided surgery for immediate anterior implants aims to reduce the time required for aesthetic and functional immediate loading. However, the limited surface area of anterior teeth for guide stabilization may affect the accuracy of implant positioning. This in vitro study evaluated the effect of the number of supporting teeth on the accuracy of immediate implants in the maxillary central incisor region.

View Article and Find Full Text PDF

Background: The success of a restoration largely depends on the quality of its fit. This study aimed to investigate the fit quality of monolithic zirconia veneers (MZVs) produced through traditional and digital workflows.

Methods: A typodont maxillary right central incisor was prepared.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!