Local delivery of drugs to the inner ear is increasingly being used in both clinical and experimental studies. Although direct injection of drugs into perilymph appears to be the most promising way of administering drugs quantitatively, no studies have yet demonstrated the pharmacokinetics in perilymph following direct injections. In this study, we have investigated the retention of substance in perilymph following a single injection into the basal turn of scala tympani (ST). The substance injected was a marker, trimethylphenylammonium (TMPA) that can be detected in low concentrations with ion-selective microelectrodes. Perilymph pharmacokinetics of TMPA was assessed using sequential apical sampling to obtain perilymph for analysis. The amount of TMPA retained in perilymph was compared for different injection and sampling protocols. TMPA concentrations measured in fluid samples were close to those predicted by simulations when the injection pipette was sealed into the bony wall of ST but were systematically lower when the injection pipette was inserted through the round window membrane (RWM). In the latter condition, it was estimated that over 60% of the injected TMPA was lost due to leakage of perilymph around the injection pipette at a rate estimated to be 0.09muL/min. The effects of leakage during and after injections through the RWM were dramatically reduced when the round window niche was filled with 1% sodium hyaluronate gel before penetrating the RWM with the injection pipette. The findings demonstrate that in order to perform quantitative drug injections into perilymph, even small rates of fluid leakage at the injection site must be controlled.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2040295PMC
http://dx.doi.org/10.1016/j.heares.2007.06.010DOI Listing

Publication Analysis

Top Keywords

injection pipette
16
round window
12
window membrane
8
injection
8
perilymph
8
tmpa
5
marker retention
4
retention cochlea
4
injections
4
cochlea injections
4

Similar Publications

Magnetic relaxation switch biosensor for detection of Vibrio parahaemolyticus based on photocleavable hydrogel.

Anal Chim Acta

January 2025

State Key Laboratory for Managing Biotic and Chemical Threats to the Quality and Safety of Agro-products, School of Material Science and Chemical Engineering, Ningbo University, Ningbo, 315211, PR China. Electronic address:

Background: Foodborne pathogens, particularly Vibrio parahaemolyticus (VP) found in seafood, pose significant health risks, including abdominal pain, nausea, and even death. Rapid, accurate, and sensitive detection of these pathogens is crucial for food safety and public health. However, existing detection methods often require complex sample pretreatment, which limits their practical application.

View Article and Find Full Text PDF
Article Synopsis
  • Bisphenol analogues (BPs) are environmental endocrine disruptors that may negatively impact human health, prompting research into their detection in bottled water.
  • This study developed a fast and efficient method using a combination of hydrophilic deep eutectic solvent and magnetic multi-walled carbon nanotubes for extracting and analyzing nine BPs through ultra-high performance liquid chromatography-tandem mass spectrometry.
  • The method showed excellent sensitivity with detection limits as low as 0.0003-0.003 μg/L and good reliability, making it effective for measuring BPs in large water samples.
View Article and Find Full Text PDF
Article Synopsis
  • The ventromedial hypothalamus (VMH) is crucial for regulating feeding behavior and the sympathetic nervous system, involving synchronized rhythmic activity known as VMH oscillation.
  • Researchers studied the cellular mechanisms behind this oscillation using techniques like electrophysiological recordings and calcium imaging in juvenile rat brain slices.
  • They found that VMH oscillation relies on persistent sodium channels and gap junctions for its rhythmic firing, and blocking these pathways disrupted the synchronized activity of VMH neurons.
View Article and Find Full Text PDF

Extracellular vesicles (EVs) are particles released from cells that facilitate intercellular communication and have tremendous diagnostic and therapeutic potential. Bulk assays lack the sensitivity to detect rare EV subsets relevant to disease, and while single EV analysis techniques remedy this, they are often undermined by complicated detection schemes and prohibitive instrumentation. To address these issues, a microfluidic technique for EV characterization called "catch and display for liquid biopsy (CAD-LB)" is proposed.

View Article and Find Full Text PDF

This study developed a rapid screening method to determine residual solvents contained in a tablet formulation using a needle-type extraction device. For this, the tablet formulation was pulverized and the powdered sample was rapidly inserted into a pipette tip. After fixing the sample with quartz wool, the pipette tip was capped with a silicon septum.