A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@remsenmedia.com&api_key=81853a771c3a3a2c6b2553a65bc33b056f08&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Design and application of an oscillatory compression device for cell constructs. | LitMetric

Mechanical compression has been shown to impact cell activity; however a need for a single device to perform a broader range of parametric studies exists. We have developed an oscillatory displacement controlled device to uniaxially strain cell constructs under both static and dynamic compression and used this device to investigate gene expression in cell constructs. The device has a wide stroke (0.25-4 mm) and frequency range (0.1-3 Hz) and several loading waveforms are possible. Alginate cellular constructs with embedded equine chondrocytes were tested and viability was maintained for the 24 h test period. Off-line mechanical testing is described and a modulus value of 18.2 +/- 1.3 kPa found for alginate disks which indicates the level of stress achieved with this deformation profile. Static (15% strain) and dynamic (15% strain, 1 Hz, triangle waveform) testing of chondrocyte constructs was performed and static compression showed significantly higher collagen II expression than dynamic using quantitative RT-PCR. In contrast, differences in matrix metalloproteinase-3 (MMP-3) expression were statistically insignificant. These studies indicate the utility of our device for studying cell activity in response to compression and suggest further studies regarding how the load and strain spectrum impact chondrocyte activity.

Download full-text PDF

Source
http://dx.doi.org/10.1002/bit.21422DOI Listing

Publication Analysis

Top Keywords

cell constructs
12
compression device
8
cell activity
8
15% strain
8
device
6
compression
5
cell
5
constructs
5
design application
4
application oscillatory
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!