Purpose: Radio-guided surgery (RGS) is an intra-operative localising technique which enables identification of tissue "marked" by a specific radiotracer injected before surgery. It is mainly used for sentinel node mapping and for detection of parathyroid adenomas and other tumours, including neuroendocrine tumours of the gastrointestinal tract (GEP-NET). The aim of this study was to determine whether intra-operative radio-detection with the use of [(99m)Tc-EDDA/HYNIC]octreotate, a new somatostatin analogue, is able to reveal an unknown primary and secondary sites, thereby improving surgical treatment and the final outcome of GEP-NET.
Methods: The study group included nine patients with suspected GEP-NET (four carcinoids, five pancreatic NET) localised with somatostatin receptor scintigraphy (with [(99m)Tc-EDDA/HYNIC]octreotate), who had negative results on other pre-operative imaging tests. At surgery, suspected tumours were measured in situ and ex vivo and precise exploration of the abdominal cavity was performed with the intra-operative scintillation detector (Navigator).
Results: Intra-operative gamma counting localised three carcinoids. In one patient SRS was false positive (owing to inflammatory infiltration). Compared with SRS, RGS revealed additional lymph node metastases in one case. RGS resulted in successful localisation of all pancreatic NET (the smallest lesion was 8 mm in diameter).
Conclusion: [(99m)Tc-EDDA/HYNIC]octreotate SRS followed by RGS is a promising technique to improve the rate of detection and efficacy of treatment of GEP-NET, especially in the presence of occult endocrine tumours. The imaging properties of [(99m)Tc-EDDA/HYNIC]octreotate and the 1-day imaging protocol offer opportunities for more widespread application of this tracer followed by RGS in oncology.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00259-007-0476-4 | DOI Listing |
Expert Rev Med Devices
December 2024
Department of Urology, Rush University Medical Center, Chicago, IL, USA.
Introduction: Recent advancements in single-port surgery, robotic platforms, 3D models and artificial intelligence have transformed surgical procedures, especially in urology. These innovations enhance precision, safety, and efficacy, reducing invasiveness and recovery times. The review focuses on the latest in robotic-assisted surgery for genitourinary cancers, highlighting the shift toward personalized, minimally invasive treatments.
View Article and Find Full Text PDFBiomedicines
October 2024
Doctoral School of Clinical Sciences, University of Pécs Medical School, 7624 Pécs, Hungary.
The incidence of non-palpable breast cancer is increasing due to widespread screening and neo-adjuvant therapies. Among the available tumor localization techniques, radio-guided occult lesion localization (ROLL) has largely replaced wire-guided localization (WGL). The aim of this study was to compare the ROLL and WGL techniques in terms of the effectiveness of isotopic marking of axillary sentinel lymph nodes and to assess patient perspectives along with surgeon and radiologist preferences.
View Article and Find Full Text PDFJ Transl Med
October 2024
Department of General Surgery, University of Pittsburgh, 200 Lothrop Street, Pittsburgh, PA, 15213, USA.
Background: Surgical resection is integral for the treatment of neuroblastoma, the most common extracranial solid malignancy in children. Safely locating and resecting primary tumor and remote deposits of disease remains a significant challenge, resulting in high rates of complications and incomplete surgery, worsening outcomes. Intraoperative molecular imaging (IMI) uses targeted radioactive or fluorescent tracers to identify and visualize tumors intraoperatively.
View Article and Find Full Text PDFAm J Surg
October 2024
Azrieli Faculty of Medicine, Bar-Ilan University, Safed, Israel; Department of Otolaryngology - Head and Neck Surgery, Galilee Medical Center, Nahariya, Israel. Electronic address:
Background: Performing MIRP procedure with a 20-fold less MIBI isotope dose allows lower radiation exposure risk for both patient and staff and reduce the overall cost of the procedure. The main goal of this systemic review and meta-analysis is to prove the non-inferiority of the very low dose MIRP compared to the standard dose.
Methods: We performed a systemic review and meta-analysis of three different electronic databases - PubMed, Web of Science and google scholar.