[A comparison of all-polyethylene and metal-backed tibial components in total knee arthroplasty].

Rev Chir Orthop Reparatrice Appar Mot

Centre Livet, Hôpital de la Croix Rousse, Hospices Civils de Lyon, 8 rue de Margnolles, 69300 Caluire.

Published: June 2007

Purpose Of The Study: The purpose of our study was to compare the clinical, functional and radiological results of two types of tibial components for the same total knee prosthesis (posterior stabilized HLS), all-polyethylene (group A) and metal-backed (group B), in order to answer the following question: does use of an all-polyethylene piece affect mid-term outcome of total knee arthroplasty (TKA)?

Material And Methods: This was a retrospective comparative analysis of a single-center non-randomized consecutive series of 169 patients with an all-polyethylene posterior stabilized cemented gliding TKA. This series was matched with another retrospective series of 169 posterior stabilized cemented TKA with a metal-backed tibial piece. Matching factors were age, gender, etiology, and follow-up. The two series were extracted from our database which included all patients who underwent surgery for a TKA in the same institution (Lyon Civil Hospices) performed by one of the authors (PN) or under his responsibility between 1987 and 1996 for group A (all-poly) and between 1987 and 1997 for group B (metal-backed). Mean follow-up was 66 months. The IKS scores and radiological findings were recorded.

Results: In group A, 96% of patients were satisfied, 93% in group B. The IKS knee score for group A was 89 +/- 10.8 and 88.3 +/- 11.9 for group B. The function score was 68 +/- 23.7 in group A and 71 +/- 24 in group B. Mean flexion was 113 degrees for both groups. Non-progressive lucent lines were noted in 27 cases in group A and 23 in group B. Revision TKA was performed for 18 knees in group A, including six with implant replacement (three of them for infection). In group B, there were ten revisions, seven with implant replacement including one with infection and three without implant replacement. The 10-year survival was 94.5% in group A and 93.64% in group B. There was no significant difference in the function and knee scores, the presence of lucent lines, and the number of implant replacements between group A and group B (p>0.05).

Discussion: This study was unable to demonstrate any superiority in clinical and radiological results for TKA between the all-polyethylene and metal-backed options at five years follow-up.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s0035-1040(07)90278-0DOI Listing

Publication Analysis

Top Keywords

group
18
total knee
12
posterior stabilized
12
implant replacement
12
all-polyethylene metal-backed
8
metal-backed tibial
8
tibial components
8
components total
8
purpose study
8
group metal-backed
8

Similar Publications

Background: Wearable sensor technologies, often referred to as "wearables," have seen a rapid rise in consumer interest in recent years. Initially often seen as "activity trackers," wearables have gradually expanded to also estimate sleep, stress, and physiological recovery. In occupational settings, there is a growing interest in applying this technology to promote health and well-being, especially in professions with highly demanding working conditions such as first responders.

View Article and Find Full Text PDF

Objectives: This study compared cognitive flexibility (CF) and emotion recognition (ER) in adolescents with eating disorders (ED) to a healthy group.

Methods: Forty healthy individuals aged 12-18 years with no psychiatric diagnosis and 46 patients diagnosed with anorexia nervosa (AN), bulimia nervosa (BN), or binge eating disorder (BED) according to DSM-5 criteria participated. CF was assessed using the Cognitive Flexibility Scale (CFS), Stroop Test, and Berg Card Sorting Test (BCST), while ER was evaluated using the test of perception of affect via nonverbal cues.

View Article and Find Full Text PDF

Background: For radiotherapy of head and neck cancer (HNC) magnetic resonance imaging (MRI) plays a pivotal role due to its high soft tissue contrast. Moreover, it offers the potential to acquire functional information through diffusion weighted imaging (DWI) with the potential to personalize treatment. The aim of this study was to acquire repetitive DWI during the course of online adaptive radiotherapy on an 1.

View Article and Find Full Text PDF

Background: Non-communicable diseases (NCDs) are the leading cause of death globally, and many humanitarian crises occur in countries with high NCD burdens. Peer support is a promising approach to improve NCD care in these settings. However, evidence on peer support for people living with NCDs in humanitarian settings is limited.

View Article and Find Full Text PDF

EZH2 inhibition induces pyroptosis via RHA-mediated S100A9 overexpression in myelodysplastic syndromes.

Exp Hematol Oncol

January 2025

Department of Hematology, the First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, Zhejiang, China.

Myelodysplastic Syndromes (MDS) represent a group of heterogeneous myeloid clonal diseases derived from aberrant hematopoietic stem/progenitor cells. Enhancer of zeste homolog 2 (EZH2) is an important regulator in gene expression through methyltransferase-dependent or methyltransferase-independent mechanisms. Herein, we found EZH2 inhibition led to MDS cell pyroptosis through RNA Helicase A (RHA) down-regulation induced overexpression of S100A9, a key regulator of inflammasome activation and pyroptosis.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!