Objective: To evaluate the significance of preoperative clinicopathological factors, including serum carcinoembryonic antigen (CEA), as well as postoperative clinicopathological factors in T1-2N1M0 patients with non-small cell lung cancer who underwent curative pulmonary resection.

Methods: Twenty T1N1M0 disease patients and 25 T2N1M0 patients underwent standard surgical procedures between September 1996 and December 2005, and were found to have non-small lung cancer. As prognostic factors, we retrospectively investigated age, sex, Brinkman index, histologic type, primary site, tumor diameter, clinical T factor, clinical N factor, pathological T factor, preoperative serum CEA levels, surgical procedure, visceral pleural involvement, and the status of lymph node involvement (level and number).

Results: The overall 5-year survival rate of all patients was 59.6%. In univariate analysis, survival was related to age (<70/>or=70 years, p=0.0079), site (peripheral/central, p=0.043), and CEA level (<5.0/>or=5.0 ng/ml, p=0.0015). However, in multivariate analysis, CEA (<5.0/>or=5.0 ng/ml) was the only independent prognostic factor; the 5-year survival of the patients with an elevated serum CEA level (>or=5.0 ng/ml) was only 33.2% compared to 79.9% in patients with a lower serum CEA level (<5.0 ng/ml).

Conclusions: An elevated serum CEA level (>or=5.0 ng/ml) was an independent predictor of survival in pN1 patients except for T3 and T4 cases. Therefore, even in completely resected pN1 non-small cell lung cancer, patients with a high CEA level might be candidates for multimodal therapy.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ejcts.2007.06.011DOI Listing

Publication Analysis

Top Keywords

cea level
16
non-small cell
12
lung cancer
12
serum cea
12
or=50 ng/ml
12
carcinoembryonic antigen
8
clinicopathological factors
8
patients
8
cell lung
8
clinical factor
8

Similar Publications

Can non-human primates extract the linear trend from a noisy scatterplot?

iScience

January 2025

Cognitive Neuroimaging Unit, CEA, INSERM, Université Paris-Saclay, NeuroSpin Center, 91191 Gif/Yvette, France.

Recent studies showed that humans, regardless of age, education, and culture, can extract the linear trend of a noisy scatterplot. Although this capacity looks sophisticated, it may simply reflect the extraction of the principal trend of the graph, as if the cloud of dots was processed as an oriented object. To test this idea, we trained Guinea baboons to associate arbitrary shapes with the increasing or decreasing trends of noiseless and noisy scatterplots, while varying the number of points, the noise level, and the regression slope.

View Article and Find Full Text PDF

To establish and validate a nomogram based on clinical characteristics and metabolic parameters derived from F-fluorodeoxyglucose positron emission tomography and computed tomography (F-FDG PET/CT) for prediction of high-grade patterns (HGP) in invasive lung adenocarcinoma. The clinical and PET/CT image data of 311 patients who were confirmed invasive lung adenocarcinoma and underwent pre-treatment F-FDG PET/CT scan in Beijing Hospital between October 2017 and March 2022 were retrospectively collected. The enrolled patients were divided into HGP group (196 patients) and non-HGP group (115 patients) according to the presence and absence of HGP.

View Article and Find Full Text PDF

: Developing ex vivo models that replicate immune-tumor interactions with high fidelity is essential for advancing immunotherapy research, as traditional two-dimensional in vitro systems often lack the complexity required to fully represent these interactions. : In this study, we establish a comprehensive 3D redirect lysis (3D-RDL) assay using colorectal cancer spheroids and adult stem cell-derived, healthy human organoids to evaluate the efficacy and safety profile of , a bispecific antibody targeting carcinoembryonic antigens (CEAs) on cancer cells and CD3 on T cells. This model allows us to assess cytotoxic activity and immune responses, capturing variations in therapeutic response not observable in simpler systems.

View Article and Find Full Text PDF

: Metered-dose inhalers (MDIs) and dry powder inhalers (DPIs) are common inhaled corticosteroid (ICS) inhaler devices. The difference in formulation and administration technique of these devices may influence oral cavity microbiota composition. We aimed to compare the saliva microbiome in children with moderate-to-severe asthma using ICS via MDIs versus DPIs.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!