A robotic cryogenic device was developed which allows freezing of thick biological tissues with millisecond time resolution. The device consists of two horizontally oriented hammers (pre-cooled with liquid N(2)) driven by two linear servo-motors. The tissue sample is bathed in Ringers contained in a chamber which drops rapidly out of the way just as the hammers approach. A third linear motor is vertically oriented, and permits the rapidly dropping chamber to smoothly decelerate. All movements were performed by the three motors and four solenoids controlled by a PC. Mechanical adjustments, that change the size of the gap between the hammers at the end position, permit the final thickness of the frozen tissue to be varied. Here we show that the freezing time increased with the square of the final thickness of the frozen bundle. However, when bundles of different original thicknesses (up to at least 1mm) were compressed to the same final thickness (e.g., 0.2mm), they exhibited nearly equal freezing times. Hence, by being able to adjust the final thickness of the frozen bundles, the device not only speeds the rate of freezing, but standardizes the freezing time for different diameter samples. This permits the use of freezing for accurate determination of the kinetics of cellular processes in biological tissue.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.cryobiol.2007.06.002DOI Listing

Publication Analysis

Top Keywords

final thickness
16
thickness frozen
12
biological tissues
8
tissues millisecond
8
millisecond time
8
time resolution
8
freezing time
8
freezing
7
controlling freezing
4
freezing process
4

Similar Publications

Hydroxycinnamic acid derivatives are a class of phenolic acid compounds, including sinapic acid, ferulic acid, and caffeic acid, which are widely found in plants. This experiment was conducted to study the effects of hydroxycinnamic acid derivatives (sinapic acid, ferulic acid, and caffeic acid) on the growth performance, muscle physical parameters, and intestinal morphology of tilapia. A total of 320 tilapia fingerlings (9.

View Article and Find Full Text PDF

Purpose: To determine the effect of wall thickness on the fracture load of hollow-structured zirconia teeth fabricated using 3D printing.

Methods: The geometry of an artificial ceramic tooth (mandibular right first molar) was copied and modified. The final test group design yielded wall thicknesses of 0.

View Article and Find Full Text PDF

Computed tomography scanning in the diagnosis of lower extremity phlebolymphedema.

J Vasc Surg Venous Lymphat Disord

January 2025

The RANE Center for Venous & Lymphatic Diseases, St. Dominic Hospital, Jackson, MS. Electronic address:

Objectives: Phlebolymphedema, the most common cause of secondary lymphedema in Western societies, seldom gets the attention it deserves. Diagnosis is often missed and when evaluated is through lymphoscintigraphy (LSG) which is cumbersome. This study aims to assess the role of computed tomography (CT) scanning in the diagnosis of phlebolymphedema of the lower extremities by comparing CT characteristics to the International Society of Lymphology (ISL) grading system and LSG.

View Article and Find Full Text PDF

Introduction: The recently proposed cerebral small vessel disease (CSVD) score system may help to capture the overall burden of CSVD. This study aimed to investigate the associations between carotid artery ultrasound features and the burden score and cognitive performance of CSVD patients.

Methods: This is a cross-sectional analysis of an ongoing prospective study.

View Article and Find Full Text PDF

Gluing is a critical step in aircraft sealing assembly, with glue profile inspection serving as the final quality assurance measure to ensure consistency and accuracy of the sealant coating, allowing timely detection and correction of defects to maintain assembly integrity and safety. Currently, existing glue inspection systems are limited to basic inspection capabilities, lack result digitization, and exhibit low efficiency. This paper proposes a 3D inspection technology for sealant coating quality based on line-structured light, enabling automated and high-precision inspection of sealant thickness, sealant width, positional accuracy, and overlap joint sealant contour through geometric computation.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!