Background: The needle biopsy technique described by Bergström is the most commonly used technique to obtain samples to assess muscle metabolism. Sampling of muscle, particularly the vastus lateralis, has become an essential tool in biomedical and clinical research. Optimal sample size is critical for availability of tissue for processing. To evaluate the effectiveness of a novel technique to obtain adequate sample size using wall suction applied to needle muscle biopsy, we collected samples from subjects in on-going clinical studies for gene expression.

Materials And Methods: Muscle biopsy samples of the vastus lateralis using 6 mm Bergström needles under local anesthesia were obtained from 55 subjects who had volunteered to participate in this research project. The vastus lateralis was biopsied according to the methods described by Bergström with a 6 mm biopsy needle. Wall suction was applied to the inner bore of the biopsy needle after the needle was inserted into the muscle.

Results: The mean sample of biopsy taken using the 6 mm was 233 mg (n = 55). The wall suction (200 mm Hg) applied to the needle pulled the surrounding tissue into the central bore of the needle. The quality of the samples was adequate for all biochemical assays. The biopsy technique did not result in any complications due to infection or bleeding.

Conclusions: Using a novel technique of connecting a 6 mm Bergström biopsy needle to wall suction, we have obtained 200 to 300 mg muscle biopsy specimens uniformly, with ease, and minimal discomfort. An increase in sample size allows for a wider variety of biochemical and histopathological analysis.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jss.2007.03.043DOI Listing

Publication Analysis

Top Keywords

wall suction
20
muscle biopsy
16
sample size
16
suction applied
12
applied needle
12
novel technique
12
vastus lateralis
12
biopsy needle
12
biopsy
10
needle
9

Similar Publications

Multi-Layer Tissue Injury of the Abdominal Wall Caused by Improper Treatment of Subcutaneous Hydrops After Liposuction.

Clin Cosmet Investig Dermatol

December 2024

Department of Plastic Reconstructive Surgery, Senior Department of Burns and Plastic Surgery, The Fourth Medical Center of Chinese PLA General Hospital, Beijing, People's Republic of China.

Liposuction has been popular with the public since its inception. The fat accumulated in the body is sucked outside the body through negative pressure suction, thereby reducing the fat cells in the body and achieving the effect of local plasticity. Although liposuction is a relatively safe procedure, due to the lack of correct judgment of the patient's condition and treatment by quite a few cosmetic practitioners, the complications of liposuction are gradually increasing.

View Article and Find Full Text PDF

Background: This study aimed to introduce and evaluate a new treatment method for rectus sheath hematoma: ultrasound-guided suction using negative pressure, curettage, and percutaneous drainage.

Methods: This retrospective study involved five patients with rectus sheath hematoma rectus sheath hematoma who had cesarean sections. For all patients, ultrasound revealed that the maximum diameter of their hematoma exceeded 70 mm.

View Article and Find Full Text PDF
Article Synopsis
  • - Colorectal cancer is highly prevalent, accounting for nearly 10% of cancers and 9.2% of annual deaths, making improved detection methods critical.
  • - Robotic "front-wheel" navigating colonoscopes provide a less painful alternative to traditional methods by reducing discomfort during examinations through enhanced anchoring technologies.
  • - The study introduces a dumbbell-shaped balloon anchoring actuator (DBAA) that improves anchoring force while minimizing trauma to the colonic wall, with experimental results supporting its effectiveness compared to traditional techniques.
View Article and Find Full Text PDF
Article Synopsis
  • The coal-breaking operation in underground mines generates substantial dust, negatively impacting air quality at the tunneling face, which poses risks for workers.
  • This study investigates a pneumatic vortex fog curtain dust control system and its effectiveness in trapping respiratory dust, revealing a significant reduction in dust concentration to 2.5 mg/m under various conditions.
  • The system shows that even with increased wind speed from auxiliary ventilation, it maintains effective dust suppression without compromising its performance, leading to improved safety and working conditions for miners.
View Article and Find Full Text PDF
Article Synopsis
  • This study analyzed the effectiveness of traditional irrigation methods using a specially designed positive pressure side-vented needle and various suction cannulas for treating mandibles with two root canals.
  • Micro-CT scans enabled detailed computational models to be created, allowing for the assessment of flow patterns, velocities, and pressures during irrigation.
  • Results indicated that using suction cannulas significantly enhanced fluid flow and wall shear stress in the complex root structures, especially in areas that conventional methods struggled to reach.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!