Background: The needle biopsy technique described by Bergström is the most commonly used technique to obtain samples to assess muscle metabolism. Sampling of muscle, particularly the vastus lateralis, has become an essential tool in biomedical and clinical research. Optimal sample size is critical for availability of tissue for processing. To evaluate the effectiveness of a novel technique to obtain adequate sample size using wall suction applied to needle muscle biopsy, we collected samples from subjects in on-going clinical studies for gene expression.
Materials And Methods: Muscle biopsy samples of the vastus lateralis using 6 mm Bergström needles under local anesthesia were obtained from 55 subjects who had volunteered to participate in this research project. The vastus lateralis was biopsied according to the methods described by Bergström with a 6 mm biopsy needle. Wall suction was applied to the inner bore of the biopsy needle after the needle was inserted into the muscle.
Results: The mean sample of biopsy taken using the 6 mm was 233 mg (n = 55). The wall suction (200 mm Hg) applied to the needle pulled the surrounding tissue into the central bore of the needle. The quality of the samples was adequate for all biochemical assays. The biopsy technique did not result in any complications due to infection or bleeding.
Conclusions: Using a novel technique of connecting a 6 mm Bergström biopsy needle to wall suction, we have obtained 200 to 300 mg muscle biopsy specimens uniformly, with ease, and minimal discomfort. An increase in sample size allows for a wider variety of biochemical and histopathological analysis.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jss.2007.03.043 | DOI Listing |
Clin Cosmet Investig Dermatol
December 2024
Department of Plastic Reconstructive Surgery, Senior Department of Burns and Plastic Surgery, The Fourth Medical Center of Chinese PLA General Hospital, Beijing, People's Republic of China.
Liposuction has been popular with the public since its inception. The fat accumulated in the body is sucked outside the body through negative pressure suction, thereby reducing the fat cells in the body and achieving the effect of local plasticity. Although liposuction is a relatively safe procedure, due to the lack of correct judgment of the patient's condition and treatment by quite a few cosmetic practitioners, the complications of liposuction are gradually increasing.
View Article and Find Full Text PDFHeliyon
October 2024
Department of Ultrasound, The First Affiliated Hospital of Shenzhen University, Shenzhen Second People's Hospital, 518035, Shenzhen, China.
Background: This study aimed to introduce and evaluate a new treatment method for rectus sheath hematoma: ultrasound-guided suction using negative pressure, curettage, and percutaneous drainage.
Methods: This retrospective study involved five patients with rectus sheath hematoma rectus sheath hematoma who had cesarean sections. For all patients, ultrasound revealed that the maximum diameter of their hematoma exceeded 70 mm.
Soft Robot
December 2024
Multiscale Medical Robotics Centre Ltd., The Chinese University of Hong Kong, Shatin, Hong Kong.
Sci Rep
December 2024
School of Mining and Coal, Inner Mongolia University of Science and Technology, Baotou, 014010, China.
Odontology
November 2024
Department of Conservative and Prosthetic Dentistry, School of Dentistry, Complutense University, Madrid, Spain.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!