A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Long-term experience with AutoCapture-controlled epicardial pacing in children. | LitMetric

Long-term experience with AutoCapture-controlled epicardial pacing in children.

Europace

Division of Pediatric Cardiology, University Children's Hospital, Steinwiesstrasse 75, 8032 Zurich, Switzerland.

Published: August 2007

Aims: To examine the feasibility and safety of AutoCapture (AC)-controlled pacing with epicardial leads in children, and study the effects on device longevity.

Methods: A total of 62 children were prospectively enrolled. Pre-discharge testing precluded AC function in six children. In 56 (90%) children, devices with AC-controlled pacing were followed up to 9years. Calculated battery life in AC-controlled pacing was compared with theoretical calculations, using a two-fold stimulation output of measured thresholds.

Results: In 53 of 56 children, no differences were observed for evoked response signals (13.3 vs. 11.5mV, P = 0.20) or lead polarization safety margins (5.5 vs. 4.1, P = 0.25) at 6-month and 4-year follow-up. A crossover to conventional pacing was required in 3 of 56 children. AC-controlled pacing prolonged the calculated battery life up to 15% for the identity and integrity devices with 0.95A h capacity, compared with theoretical conventional settings (P = 0.008). In patients with ventricular pacing thresholds >1.5V at 0.5ms, battery life was increased by 30% compared with theoretical conventional settings (P < 0.001).

Conclusion: AC-controlled pacing with epicardial leads is feasible and safe in children during long-term follow-up. An adequate lead polarization safety margin persists in most patients. Calculated battery life was prolonged up to 15% with AC-controlled pacing. Patients with high or fluctuating pacing thresholds benefit the most.

Download full-text PDF

Source
http://dx.doi.org/10.1093/europace/eum130DOI Listing

Publication Analysis

Top Keywords

ac-controlled pacing
24
battery life
16
calculated battery
12
compared theoretical
12
pacing
10
children
8
pacing epicardial
8
epicardial leads
8
lead polarization
8
polarization safety
8